Overview
Date 2007 Mar 21
PMID 17367354
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: T-wave alternans (TWA) is a promising electrocardiogram (ECG) predictor of sudden cardiac arrest, yet needs specialized recordings for conventional spectral analysis. Modified moving average (MMA) analysis is a new approach that can measure TWA from routine ECGs, thus widening its applicability. However, MMA-TWA has not been calibrated against spectral TWA nor outcome in high risk patients. We hypothesized that spectral and MMA-TWA would both predict arrhythmia-free survival on long-term prospective follow-up.

Methods And Results: In 41 patients with left ventricular systolic dysfunction (ejection fraction 31 +/- 13%), we studied TWA simultaneously using spectral and MMA during pacing (< 110 beats/min). MMA amplified TWA over spectral analyses (13.0 +/- 8.28 microV vs 1.96 +/- 5.15 microV, P < 0.001). On 542 +/- 311 days' follow-up, from clinic visits, telephonic interviews, and device interrogations, there were 11 deaths or sustained ventricular arrhythmias ('events'). Positive spectral TWA (>or=1.9 microV) identified patients with from those without events (P = 0.02). Receiver-operating characteristics for MMA-TWA showed that the cutpoint >or= 10.75 microV was optimal for the combined endpoint. Kaplan-Meier analysis using this MMA-TWA cutpoint trended to predict events (P = 0.06), while MMA combined with spectral TWA identified events (P = 0.01).

Conclusions: MMA amplifies TWA compared to traditional spectral analyses, but both likely reflect similar pathophysiology. Validation in larger populations will enable MMA-TWA to be widely applied to stratify risk for sudden cardiac arrest.

Citing Articles

Microvolt T-wave alternans in young myocardial infarction patients with preserved cardiac function treated with single-vessel primary percutaneous coronary intervention.

Somuncu M, Erturk M, Karakurt H, Demir A, Bulut U, Kurtar A Arch Med Sci Atheroscler Dis. 2017; 1(1):e68-e74.

PMID: 28905024 PMC: 5421539. DOI: 10.5114/amsad.2016.61494.


Utility of T-wave alternans during night time as a predictor for ventricular fibrillation in patients with Brugada syndrome.

Sakamoto S, Takagi M, Tatsumi H, Doi A, Sugioka K, Hanatani A Heart Vessels. 2015; 31(6):947-56.

PMID: 25989739 DOI: 10.1007/s00380-015-0692-y.


Microvolt T-wave alternans physiological basis, methods of measurement, and clinical utility--consensus guideline by International Society for Holter and Noninvasive Electrocardiology.

Verrier R, Klingenheben T, Malik M, El-Sherif N, Exner D, Hohnloser S J Am Coll Cardiol. 2011; 58(13):1309-24.

PMID: 21920259 PMC: 4111570. DOI: 10.1016/j.jacc.2011.06.029.


A nonparametric surrogate-based test of significance for T-wave alternans detection.

Nemati S, Abdala O, Monasterio V, Yim-Yeh S, Malhotra A, Clifford G IEEE Trans Biomed Eng. 2010; 58(5):1356-64.

PMID: 20409986 PMC: 2991534. DOI: 10.1109/TBME.2010.2047859.


Risk stratification for sudden cardiac death: is there a clinical role for T wave alternans?.

Cutler M, Rosenbaum D Heart Rhythm. 2009; 6(8 Suppl):S56-61.

PMID: 19631909 PMC: 2761079. DOI: 10.1016/j.hrthm.2009.05.025.