» Articles » PMID: 17334309

Microvascular Flap Reconstruction by Otolaryngologists: Prevalence, Postoperative Care, and Monitoring Techniques

Overview
Journal Laryngoscope
Date 2007 Mar 6
PMID 17334309
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Background/objectives: Microvascular "free flap" transplants have become the preferred method of reconstruction for a great variety of complicated head and neck defects. As recently as 10 years ago, having a microvascular surgeon within a department of otolaryngology was the exception rather than the rule, whereas it is our impression that today most academic programs have one or more microvascularly trained head and neck surgeons. Among microvascular surgeons, postoperative care and management regimens vary greatly. Through informal conversations, we discerned that some surgeons take a very aggressive approach to monitoring, perhaps including prolonged stays in an intensive care setting with implanted Doppler devices to monitor flap blood flow and intravenous administration of dextran or other pharmaceutical projects. Others report that patients are quickly discharged from the hospital after just aspirin and subcutaneous heparin for a few days. Some physicians perform "flap checks" hourly, whereas others have residents check only once daily.

Design/methods: We surveyed academic otolaryngology-head and neck surgery departments that sponsor residency programs in the United States to 1) determine the prevalence of microvascular trained otolaryngologists within training programs and 2) assess variations in postoperative and monitoring regimens.

Results: We found that on average, 12.2% of otolaryngologists per department perform free flap transplants, and 71.6% of microvascular trained surgeons continue to do free flaps. The surgeons self reported a 96.4% average success rate and a 6.88% return rate to the operating room for complications. Monitoring methods used included flap color (used by 79.4% of surgeons), Doppler signal (79.4%), pin prick and bleeding rate (67.6%), capillary refill (61.8%), skin surface temperature (11.8%), and implanted Doppler (8.8%). Anticoagulants used included aspirin (used by 76.5% of microvascular surgeons), low-molecular-weight dextran (35.3%), and subcutaneous heparin (26.5%).

Conclusions: Microvascular training has become commonplace in otolaryngology-head and neck surgery training programs, with more than one in eight of these academic physicians reporting microvascular training. There was no self-reported difference in flap failure rates on the basis of postoperative care and monitoring regimen. The results of this survey suggest that a simplified consensus postoperative regimen can be recommended.

Citing Articles

Study on Blood Circulation Monitoring After the Tissue Transfer of Ultrathin or Conventional Anterolateral Thigh Flaps.

Zhou Z, Yu L, Meng F, Wen J, Xiao Y, Wan S Plast Reconstr Surg Glob Open. 2024; 12(11):e6337.

PMID: 39574493 PMC: 11581755. DOI: 10.1097/GOX.0000000000006337.


Consecutive Microsurgical Cases Performed by Single Surgeon at a Canadian Tertiary Care Center: A Retrospective Review.

Chen A, Gormley J, Olaiya O, Voineskos S, Coroneos C, Avram R Plast Surg (Oakv). 2024; :22925503241234934.

PMID: 39553504 PMC: 11561944. DOI: 10.1177/22925503241234934.


Smartphone-based thermal imaging for pedicled skin flaps: a pilot study toward objective perfusion assessment in facial, head, and neck reconstruction.

Fiedler L, Tobias M, Burkard L, Lukas A Eur Arch Otorhinolaryngol. 2024; .

PMID: 39443388 DOI: 10.1007/s00405-024-09048-3.


Prompt, Objective, and Accurate Measurement of Rat Abdominal Flap Blood Flow Using Laser Speckle Flowgraphy.

Tsunekawa K, Takashimizu I, Yuzuriha S Plast Reconstr Surg Glob Open. 2024; 12(8):e6062.

PMID: 39129849 PMC: 11315587. DOI: 10.1097/GOX.0000000000006062.


Perfusion in Pedicled Skin Flaps: Initial Insights from Smartphone-Based Thermal Imaging Protocol.

Fiedler L, Lippert B, Adrian L, Meyer T J Pers Med. 2024; 14(7).

PMID: 39063984 PMC: 11278002. DOI: 10.3390/jpm14070730.