» Articles » PMID: 17314154

Amniotic Membrane Transplantation for Ocular Disease: a Review of the First 233 Cases from the UK User Group

Overview
Journal Br J Ophthalmol
Specialty Ophthalmology
Date 2007 Feb 23
PMID 17314154
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Amniotic membrane transplantation (AMT), as a new tool in the armamentarium of therapies available for ocular surface problems, became widely available in the UK in 1998. This study evaluates the indications for treatment, the surgical procedures used, and the results of a subset of the first AMT cases carried out by the group using this nationally available supply. This user group model provides data which is different from that obtained from uncontrolled case series, or clinical trials, and may be more representative of the outcomes that can be expected when a procedure becomes widely available.

Methods: The first 233 AMTs, performed by the UK user group, were evaluated by audit and outcomes were assessed at 3 months.

Results: Of the 233 transplants, there were 126 (54.1%) valid outcome returns: the outcome for persistent epithelial defects was a healed and stable surface in 11/35 (31.4%, 95% CI 16.9 to 49.3); for chemical/thermal injuries, a healed uninflamed eye with clear cornea in 5/18 (27.8%, 95% CI 9.7 to 53.4); for bullous keratopathy a pain-free, stable surface without bullae in 4/18 (22.2%, 95% CI 6.4 to 47.6); for ocular surface reconstruction, an epithelialised uninflamed conjunctiva without scarring in 12/23 (52.2%, 95% CI 30.6 to 73.2); and for limbal stem cell deficiency, a corneal phenotype in 4/7 (57.1%). The operative technique least associated with failure was use of a bandage contact lens at the end of the procedure (OR 0.19, 95% CI 0.06 to 0.59, p = 0.004). Previous treatment with topical steroids was significantly associated with failure (OR 5.70, 95% CI 1.77 to 18.43, p = 0.004).

Conclusion: Although the outcome criteria used in this study were stringent, and the follow-up duration was short, the results of AMT by this user group were generally less favourable than those of previously reported case series. Controlled clinical trials would improve the quality of evidence for use of amniotic membrane in ocular disease.

Citing Articles

Application of Fetal Membranes and Natural Materials for Wound and Tissue Repair.

Rouzaire M, Blanchon L, Sapin V, Gallot D Int J Mol Sci. 2024; 25(22).

PMID: 39595963 PMC: 11594142. DOI: 10.3390/ijms252211893.


Tarsorrhaphy with Sutureless Amnion Transplantation: Practical Management of Ocular Surface Pathologies.

Ozcan A, Ulas B, Ciloglu E Beyoglu Eye J. 2023; 7(4):313-319.

PMID: 36628076 PMC: 9794511. DOI: 10.14744/bej.2022.10327.


Japan: Diagnosis and Management of Stevens-Johnson Syndrome/Toxic Epidermal Necrolysis With Severe Ocular Complications.

Sotozono C, Ueta M, Kinoshita S Front Med (Lausanne). 2021; 8:657327.

PMID: 34395463 PMC: 8355416. DOI: 10.3389/fmed.2021.657327.


Bioaugmentation in the surgical treatment of anterior cruciate ligament injuries: A review of current concepts and emerging techniques.

Looney A, Leider J, Horn A, Bodendorfer B SAGE Open Med. 2020; 8:2050312120921057.

PMID: 32435488 PMC: 7222656. DOI: 10.1177/2050312120921057.


The application of human amniotic membrane in the surgical management of limbal stem cell deficiency.

Le Q, Deng S Ocul Surf. 2019; 17(2):221-229.

PMID: 30633967 PMC: 6529245. DOI: 10.1016/j.jtos.2019.01.003.


References
1.
Meller D, Pires R, Mack R, Figueiredo F, Heiligenhaus A, Park W . Amniotic membrane transplantation for acute chemical or thermal burns. Ophthalmology. 2000; 107(5):980-9; discussion 990. DOI: 10.1016/s0161-6420(00)00024-5. View

2.
Espana E, Grueterich M, Sandoval H, Solomon A, Alfonso E, Karp C . Amniotic membrane transplantation for bullous keratopathy in eyes with poor visual potential. J Cataract Refract Surg. 2003; 29(2):279-84. DOI: 10.1016/s0886-3350(02)01525-0. View

3.
Schwab I, Reyes M, Isseroff R . Successful transplantation of bioengineered tissue replacements in patients with ocular surface disease. Cornea. 2000; 19(4):421-6. DOI: 10.1097/00003226-200007000-00003. View

4.
Letko E, Stechschulte S, Kenyon K, Sadeq N, Romero T, Samson C . Amniotic membrane inlay and overlay grafting for corneal epithelial defects and stromal ulcers. Arch Ophthalmol. 2001; 119(5):659-63. DOI: 10.1001/archopht.119.5.659. View

5.
Adds P, Hunt C, Dart J . Amniotic membrane grafts, "fresh" or frozen? A clinical and in vitro comparison. Br J Ophthalmol. 2001; 85(8):905-7. PMC: 1724096. DOI: 10.1136/bjo.85.8.905. View