Endovascular Repair of Acute Type B Aortic Dissection: Long-term Follow-up of True and False Lumen Diameter Changes

Overview
Journal Ann Thorac Surg
Publisher Elsevier
Date 2007 Feb 20
PMID 17307460
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The aim of this study was to determine the technical success after endovascular treatment of acute type B aortic dissections and to evaluate true and false lumen diameter changes at long-term follow-up.

Methods: Twenty-eight patients with acute type B-dissection who were treated by stent graft repair presented with rupture (n = 1), contained rupture (n = 2), compromised branch vessels (n = 14), pleural effusion (n = 11), rapid aortic diameter progression (n = 5), persistent pain (n = 3), refractory hypertension (n = 10), and an aortic diameter of more than 4 cm (n = 4). Taking into account the perfusion status of the false lumen, diameter changes were monitored in the thoracic aorta at the level of the stented segment (L1), distal to the stent graft (L2), and at the level of the celiac trunk (L3).

Results: Severe complications in 9 patients (32%) resulted in 3 deaths for a 30-day mortality rate of 10.7%. Primary sealing of the entry tear was achieved in 86%. At all levels, the true lumen diameter increased significantly after stent graft placement. At the 1-year follow-up, the false lumen in L1 was thrombosed in 90% and the mean difference of diameter reduction was highly significant. In L2, complete false lumen thrombosis occurred in 60% with a significant diameter decrease. In L3, the false lumen thrombosed in only 22%, and the mean difference of false lumen diameter increase reached significance at the 2-year follow-up.

Conclusions: Ninety percent of patients were treated successfully with thrombosis of the false lumen in the stented segment. False lumen perfusion distal to the stent graft resulted in diameter increase in several patients leaving these segments an area of concern.

Citing Articles

Endovascular repair of acute complicated type B aortic dissection-systematic review and meta-analysis of long-term survival and reintervention.

Wilson-Smith A, Muston B, Kamalanathan H, Yung A, Chen C, Sahai P Ann Cardiothorac Surg. 2021; 10(6):723-730.

PMID: 34926176 PMC: 8640884. DOI: 10.21037/acs-2021-taes-17.


Endovascular Stent-Graft Repair of the Ascending Aorta: Assessment of a Specific Novel Stent-Graft Design in Phantom, Cadaveric, and Clinical Application.

Hauck S, Kupferthaler A, Stelzmuller M, Eilenberg W, Ehrlich M, Neumayer C Cardiovasc Intervent Radiol. 2021; 44(9):1448-1455.

PMID: 34180002 PMC: 8382630. DOI: 10.1007/s00270-021-02859-5.


Comparison of diametric and volumetric changes in Stanford type B aortic dissection patients in assessing aortic remodeling post-stent graft treatment.

Wan Ab Naim W, Sun Z, Liew Y, Chan B, Jansen S, Lei J Quant Imaging Med Surg. 2021; 11(5):1723-1736.

PMID: 33936960 PMC: 8047377. DOI: 10.21037/qims-20-814.


Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents.

Costache V, Meekel J, Costache A, Melnic T, Solomon C, Chitic A Materials (Basel). 2020; 13(10).

PMID: 32429089 PMC: 7287707. DOI: 10.3390/ma13102274.


Impact of Modified Frozen Elephant Trunk Procedure on Downstream Aorta Remodeling in Acute Aortic Dissection: CT Scan Follow-Up.

Koechlin L, Kaufmann J, Macius E, Bremerich J, Sommer G, Gahl B World J Surg. 2020; 44(5):1648-1657.

PMID: 31933041 DOI: 10.1007/s00268-020-05374-9.