Anatomical Flow Phantoms of the Nonplanar Carotid Bifurcation, Part I: Computer-aided Design and Fabrication

Overview
Specialty Radiology
Date 2007 Feb 20
PMID 17306699
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

Doppler ultrasound is widely used in the diagnosis and monitoring of arterial disease. Current clinical measurement systems make use of continuous and pulsed ultrasound to measure blood flow velocity; however, the uncertainty associated with these measurements is great, which has serious implications for the screening of patients for treatment. Because local blood flow dynamics depend to a great extent on the geometry of the affected vessels, there is a need to develop anatomically accurate arterial flow phantoms with which to assess the accuracy of Doppler blood flow measurements made in diseased vessels. In this paper, we describe the computer-aided design and manufacturing (CAD-CAM) techniques that we used to fabricate anatomical flow phantoms based on images acquired by time-of-flight magnetic resonance imaging (TOF-MRI). Three-dimensional CAD models of the carotid bifurcation were generated from data acquired from sequential MRI slice scans, from which solid master patterns were made by means of stereolithography. Thereafter, an investment casting procedure was used to fabricate identical flow phantoms for use in parallel experiments involving both laser and Doppler ultrasound measurement techniques.

Citing Articles

Fabrication of deformable patient-specific AAA models by material casting techniques.

Antonuccio M, Gasparotti E, Bardi F, Monteleone A, This A, Rouet L Front Cardiovasc Med. 2023; 10:1141623.

PMID: 37753165 PMC: 10518418. DOI: 10.3389/fcvm.2023.1141623.


A Brief Review for Common Doppler Ultrasound Flow Phantoms.

Shalbi S, Oglat A, Albarbar B, Elkut F, Qaeed M, Arra A J Med Ultrasound. 2020; 28(3):138-142.

PMID: 33282656 PMC: 7709522. DOI: 10.4103/JMU.JMU_96_19.


Biomechanical Investigation of Disturbed Hemodynamics-Induced Tissue Degeneration in Abdominal Aortic Aneurysms Using Computational and Experimental Techniques.

Salman H, Ramazanli B, Yavuz M, Yalcin H Front Bioeng Biotechnol. 2019; 7:111.

PMID: 31214581 PMC: 6555197. DOI: 10.3389/fbioe.2019.00111.


Chemical Items Used for Preparing Tissue-Mimicking Material of Wall-Less Flow Phantom for Doppler Ultrasound Imaging.

Oglat A, Matjafri M, Suardi N, Oqlat M, Abdelrahman M, Oqlat A J Med Ultrasound. 2018; 26(3):123-127.

PMID: 30283197 PMC: 6159330. DOI: 10.4103/JMU.JMU_13_17.


Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow.

Funamoto K, Yamashita O, Hayase T J Med Ultrason (2001). 2015; 42(1):17-23.

PMID: 26578486 DOI: 10.1007/s10396-014-0560-x.