» Articles » PMID: 17293522

Reaerosolization of Fluidized Spores in Ventilation Systems

Overview
Date 2007 Feb 13
PMID 17293522
Citations 8
Authors
Affiliations
Soon will be listed here.
Abstract

This project examined dry, fluidized spore reaerosolization in a heating, ventilating, and air conditioning duct system. Experiments using spores of Bacillus atrophaeus, a nonpathogenic surrogate for Bacillus anthracis, were conducted to delineate the extent of spore reaerosolization behavior under normal indoor airflow conditions. Short-term (five air-volume exchanges), long-term (up to 21,000 air-volume exchanges), and cycled (on-off) reaerosolization tests were conducted using two common duct materials. Spores were released into the test apparatus in turbulent airflow (Reynolds number, 26,000). After the initial pulse of spores (approximately 10(10) to 10(11) viable spores) was released, high-efficiency particulate air filters were added to the air intake. Airflow was again used to perturb the spores that had previously deposited onto the duct. Resuspension rates on both steel and plastic duct materials were between 10(-3) and 10(-5) per second, which decreased to 10 times less than initial rates within 30 min. Pulsed flow caused an initial spike in spore resuspension concentration that rapidly decreased. The resuspension rates were greater than those predicted by resuspension models for contamination in the environment, a result attributed to surface roughness differences. There was no difference between spore reaerosolization from metal and that from plastic duct surfaces over 5 hours of constant airflow. The spores that deposited onto the duct remained a persistent source of contamination over a period of several hours.

Citing Articles

Particulate matter resuspension from simulated urban green floors using a wind tunnel-mounted closed chamber.

Seo I, Park C, Yoo G PeerJ. 2023; 11:e14674.

PMID: 36785709 PMC: 9921991. DOI: 10.7717/peerj.14674.


Impact of filter material and holding time on spore sampling efficiency in water.

Ratliff K, Abdel-Hady A, Monge M, Mikelonis A, Touati A Lett Appl Microbiol. 2023; 76(2).

PMID: 36705271 PMC: 10599418. DOI: 10.1093/lambio/ovad005.


Viruses such as SARS-CoV-2 can be partially shielded from UV radiation when in particles generated by sneezing or coughing: Numerical simulations.

Doughty D, Hill S, Mackowski D J Quant Spectrosc Radiat Transf. 2021; 262:107489.

PMID: 33518804 PMC: 7836904. DOI: 10.1016/j.jqsrt.2020.107489.


Aerosol and Surface Deposition Characteristics of Two Surrogates for Bacillus anthracis Spores.

Bishop A, Stapleton H Appl Environ Microbiol. 2016; 82(22):6682-6690.

PMID: 27613681 PMC: 5086562. DOI: 10.1128/AEM.02052-16.


Evaluation of sampling methods for Bacillus spore-contaminated HVAC filters.

Calfee M, Rose L, Tufts J, Morse S, Clayton M, Touati A J Microbiol Methods. 2013; 96:1-5.

PMID: 24184312 PMC: 4969623. DOI: 10.1016/j.mimet.2013.10.012.


References
1.
. Update: Investigation of bioterrorism-related anthrax, 2001. MMWR Morb Mortal Wkly Rep. 2001; 50(45):1008-10. View

2.
Dull P, Wilson K, Kournikakis B, Whitney E, Boulet C, Ho J . Bacillus anthracis aerosolization associated with a contaminated mail sorting machine. Emerg Infect Dis. 2002; 8(10):1044-7. PMC: 2730297. DOI: 10.3201/eid0810.020356. View

3.
Weis C, Intrepido A, Miller A, Cowin P, Durno M, Gebhardt J . Secondary aerosolization of viable Bacillus anthracis spores in a contaminated US Senate Office. JAMA. 2002; 288(22):2853-8. DOI: 10.1001/jama.288.22.2853. View

4.
INGLESBY T, Henderson D, Bartlett J, Ascher M, Eitzen E, Friedlander A . Anthrax as a biological weapon: medical and public health management. Working Group on Civilian Biodefense. JAMA. 1999; 281(18):1735-45. DOI: 10.1001/jama.281.18.1735. View

5.
Meselson M, Guillemin J, Hugh-Jones M, Langmuir A, Popova I, Shelokov A . The Sverdlovsk anthrax outbreak of 1979. Science. 1994; 266(5188):1202-8. DOI: 10.1126/science.7973702. View