» Articles » PMID: 1729025

Producing and Avoiding Stress Shielding. Laboratory and Clinical Observations of Noncemented Total Hip Arthroplasty

Overview
Publisher Wolters Kluwer
Specialty Orthopedics
Date 1992 Jan 1
PMID 1729025
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

Experimental canine model studies of stiff versus flexible, fully porous-coated, metallic femoral stems (differing by three- to fivefold in stiffness characteristics) revealed markedly different resorptive bone remodeling patterns. The flexible stem resulted in about 30% more cortical bone retention adjacent to the implant at one-year postimplantation and larger differences in dogs killed two and three years after surgery. Strain-gauge studies confirmed that there are differences in cortical bone strains with the two stem designs, the flexible stem producing a more uniform and more nearly normal strain distribution medially. Differences in cortical bone remodeling were quantified using dual energy X-ray absorptiometry (DEXA). The bone mineral content in femora with the flexible stem decreased less than 20%, compared to normal. At three years postimplantation, the bone mineral content of the femora with the stiff stem was about 50% that of the femora with the flexible stem. Clinically, DEXA revealed that 5%-15% changes in bone mineral density at various periimplant sites were common within the first two years after surgery; these changes were not usually evident roentgenographically. Serial roentgenographically distinct bone resorption was usually associated with bone mineral density changes of 20%-50%. Five- to 13-year roentgenographic follow-up observations of 213 cases with the Anatomic Medullary Locking prosthesis showed that pronounced bone resorption occurred in 33% of patients. Larger stems (greater than 13 mm in diameter) and stems with extensive porous coating had a significantly higher incidence of pronounced bone resorption than smaller stems and those with proximal coating. The stiffness characteristics of the human femur were established as a function of canal size and compared with those of noncemented hip prostheses. Increased mechanical compatibility was found for stems made of titanium alloy and with design features that reduce cross-sectional area and moment of inertia. Clinical data suggest that to reduce the likelihood of pronounced bone resorption, it would be beneficial for the implant to possess a bending stiffness of about one half to one third that of the human femur.

Citing Articles

Current trends in shoulder arthroplasty - Are the trends backed by evidence?.

Shields D, Sewpaul Y, Sandeep K, Atherton C, Goffin J, Rashid M J Clin Orthop Trauma. 2025; 62:102897.

PMID: 39872122 PMC: 11762636. DOI: 10.1016/j.jcot.2024.102897.


Allograft-prosthesis composite after proximal femur bone tumor resection in pediatric age: Is it effective in preserving bone stock?.

Campanacci D, Scanferla R, Muratori F, Scolari F, Scoccianti G, Tamburini A J Child Orthop. 2024; 18(5):531-539.

PMID: 39421396 PMC: 11483815. DOI: 10.1177/18632521241269338.


Comparing the Efficacy of Antiosteoporotic Drugs in Preventing Periprosthetic Bone Loss Following Total Hip Arthroplasty: A Systematic Review and Bayesian Network Meta-Analysis.

Tang Y, Jin Z, Lu Y, Chen L, Lv S, Xu T Orthop Surg. 2024; 16(10):2344-2354.

PMID: 39056482 PMC: 11456730. DOI: 10.1111/os.14165.


Preventing Loss of Femoral Periprosthetic Bone Mineral Density in Cementless Total Hip Arthroplasty Using a Tapered Wedge Stem: A Retrospective, Cohort Study in Osteoporotic Patients Treated with Denosumab.

Kamo K, Kijima H, Okuyama K, Kawano T, Seki N, Sato C Cureus. 2024; 16(5):e59908.

PMID: 38721477 PMC: 11078518. DOI: 10.7759/cureus.59908.


Examining the Association Between the Extent of Anterior Longitudinal Ligament Ossification Progression and Comorbidities in Diffuse Idiopathic Skeletal Hyperostosis.

Ishimura D, Morino T, Murakami Y, Yamaoka S, Kinoshita T, Takao M Cureus. 2024; 15(12):e51357.

PMID: 38292970 PMC: 10824704. DOI: 10.7759/cureus.51357.