Conversion of CT Numbers into Tissue Parameters for Monte Carlo Dose Calculations: a Multi-centre Study

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2007 Jan 18
PMID 17228104
Citations 26
Authors
Affiliations
Soon will be listed here.
Abstract

The conversion of computed tomography (CT) numbers into material composition and mass density data influences the accuracy of patient dose calculations in Monte Carlo treatment planning (MCTP). The aim of our work was to develop a CT conversion scheme by performing a stoichiometric CT calibration. Fourteen dosimetrically equivalent tissue subsets (bins), of which ten bone bins, were created. After validating the proposed CT conversion scheme on phantoms, it was compared to a conventional five bin scheme with only one bone bin. This resulted in dose distributions D(14) and D(5) for nine clinical patient cases in a European multi-centre study. The observed local relative differences in dose to medium were mostly smaller than 5%. The dose-volume histograms of both targets and organs at risk were comparable, although within bony structures D(14) was found to be slightly but systematically higher than D(5). Converting dose to medium to dose to water (D(14) to D(14wat) and D(5) to D(5wat)) resulted in larger local differences as D(5wat) became up to 10% higher than D(14wat). In conclusion, multiple bone bins need to be introduced when Monte Carlo (MC) calculations of patient dose distributions are converted to dose to water.

Citing Articles

A Review on the Use of Imaging Biomarkers in Oncology Clinical Trials: Quality Assurance Strategies for Technical Validation.

Chauvie S, Mazzoni L, ODoherty J Tomography. 2023; 9(5):1876-1902.

PMID: 37888741 PMC: 10610870. DOI: 10.3390/tomography9050149.


HU-based material conversion for BNCT accurate dose estimation.

Teng Y, Chen J, Zhong W, Liu Y Sci Rep. 2023; 13(1):15701.

PMID: 37735580 PMC: 10514297. DOI: 10.1038/s41598-023-42508-0.


A discrete ordinates Boltzmann solver for application to inverse planning of photons and protons.

Bedford J Phys Med Biol. 2023; 68(18).

PMID: 37643625 PMC: 10498099. DOI: 10.1088/1361-6560/acf4de.


A phase space model of a Versa HD linear accelerator for application to Monte Carlo dose calculation in a real-time adaptive workflow.

Bedford J, Nilawar R, Nill S, Oelfke U J Appl Clin Med Phys. 2022; 23(9):e13663.

PMID: 35699201 PMC: 9512357. DOI: 10.1002/acm2.13663.


Investigation of tube voltage dependence on CT number and its effect on dose calculation algorithms using thorax phantom in Monaco treatment planning system for external beam radiation therapy.

Saini A, Pandey V, Kumar P, Singh A, Pasricha R J Med Phys. 2022; 46(4):315-323.

PMID: 35261502 PMC: 8853450. DOI: 10.4103/jmp.JMP_124_20.