Application of a Calibration Method Provides More Realistic Results for a Finite Element Model of a Lumbar Spinal Segment

Overview
Date 2007 Jan 6
PMID 17204355
Citations 73
Authors
Affiliations
Soon will be listed here.
Abstract

Background: An important step in finite element modeling is the process of validation to derive clinical relevant data. It can be assumed that defect states of a finite element model, which have not been validated before, may predict wrong results. The purpose of this study was to show the differences in accuracy between a calibrated and a non-calibrated finite element model of a lumbar spinal segment for different clinical defects.

Methods: For this study, two geometrically identical finite element models were used. An in vitro experiment was designed, deriving data for the calibration. Frequently used material properties were obtained from the literature and transferred into the non-calibrated model. Both models were validated on three clinical defects: bilateral hemifacetectomy, nucleotomy and interspinous defects, whereas in vitro range of motion data served as control points. Predictability and accuracy of the calibrated and non-calibrated finite element model were evaluated and compared.

Findings: Both finite element models could mimic the intact situation with a good agreement. In the defects, the calibrated model predicted motion behavior with excellent agreement, whereas the non-calibrated model diverged greatly.

Interpretation: Investigating the biomechanical performance of implants and load distribution of different spinal structures by numerical analysis requires not only good agreement with the intact segment, but also with the defect states, which are initiated prior to implant insertion. Because of more realistic results the calibration method may be recommended, however, it is more time consuming.

Citing Articles

Biomechanical effects of altered multifidus muscle morphology on cervical spine tissues.

Xu G, Li C, Sheng Z Front Bioeng Biotechnol. 2025; 13:1524844.

PMID: 40051837 PMC: 11882557. DOI: 10.3389/fbioe.2025.1524844.


Multiscale dynamics analysis of lumbar vertebral cortical bone based on the Abaqus submodel finite element method.

Ju C, Yang K, Yang Q, Mi Y, Wang C, Ji H Sci Rep. 2025; 15(1):6861.

PMID: 40011636 PMC: 11865512. DOI: 10.1038/s41598-025-91918-9.


Posterior Ligamentum Complex Preservation Alleviate ASD-Related Biomechanical Deterioration in Lumbar Interbody Fusion Models: A Finite Element Analysis.

He L, Zhu T, Cai W, Yang W, Chen Z, Li J JOR Spine. 2025; 8(1):e70030.

PMID: 39781090 PMC: 11705535. DOI: 10.1002/jsp2.70030.


A M-PEEK rod system to stabilize spinal motion after graded facetectomy: a finite element study.

Li Y, Shih S, Chen H BMC Musculoskelet Disord. 2024; 25(1):838.

PMID: 39438854 PMC: 11494999. DOI: 10.1186/s12891-024-07949-2.


Biomechanical effects of endplate sagittal coverage change on cervical disc replacement: a finite element analysis.

Chen L, Wang H, Xu G, Liu H Front Bioeng Biotechnol. 2024; 12:1371548.

PMID: 39267905 PMC: 11390515. DOI: 10.3389/fbioe.2024.1371548.