» Articles » PMID: 17191242

Actual Flip-angle Imaging in the Pulsed Steady State: a Method for Rapid Three-dimensional Mapping of the Transmitted Radiofrequency Field

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2006 Dec 28
PMID 17191242
Citations 407
Authors
Affiliations
Soon will be listed here.
Abstract

A new method has been developed for fast image-based measurements of the transmitted radiofrequency (RF) field. The method employs an actual flip-angle imaging (AFI) pulse sequence that consists of two identical RF pulses followed by two delays of different duration (TR(1) < TR(2)). After each pulse, a gradient-echo (GRE) signal is acquired. It has been shown theoretically and experimentally that if delays TR(1) and TR(2) are sufficiently short and the transverse magnetization is completely spoiled, the ratio r = S(2)/S(1) of signal intensities S(1) and S(2), acquired at the beginning of the time intervals TR(1) and TR(2), depends on the flip angle (FA) of applied pulses as r = (1 + n * cos(FA))/(n + cos(FA)), where n = TR(2)/TR(1). The method allows fast 3D implementation and provides accurate B(1) measurements that are highly insensitive to T(1). The unique feature of the AFI method is that it uses a pulsed steady-state signal acquisition. This overcomes the limitation of previous methods that required long relaxation delays between sequence repetitions. The method has been shown to be useful for time-efficient whole-body B(1) mapping and correction of T(1) maps obtained using a variable FA technique in the presence of nonuniform RF excitation.

Citing Articles

Evaluation of magnetic resonance spectroscopy total sodium concentration measures, and associations with microstructure and physical impairment in cervical myelopathy.

Solanky B, Prados F, Tur C, Grussu F, Al-Ahmad S, Yang X Sci Rep. 2025; 15(1):7014.

PMID: 40016502 PMC: 11868613. DOI: 10.1038/s41598-025-91658-w.


UTE MRI technical developments and applications in osteoporosis: a review.

Shin S, Chae H, Suprana A, Jerban S, Chang E, Shi L Front Endocrinol (Lausanne). 2025; 16:1510010.

PMID: 39980853 PMC: 11839439. DOI: 10.3389/fendo.2025.1510010.


Development of a Double Tuned H/P Whole-Body Birdcage Transmit Coil for H and P MR Applications From Head to Toe at 7 T.

Gursan A, Kahraman-Agir B, Gosselink M, Welting D, Froeling M, Hoogduin H NMR Biomed. 2025; 38(3):e5325.

PMID: 39888087 PMC: 11783138. DOI: 10.1002/nbm.5325.


Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values.

Saunders A, Kim M, Gao C, Remedios L, Krishnan A, Schilling K Magn Reson Imaging. 2025; 117:110322.

PMID: 39756665 PMC: 11832054. DOI: 10.1016/j.mri.2025.110322.


Optimized radiofrequency shimming using low-heating B1+-mapping in the presence of deep brain stimulation implants: Proof of concept.

Arianpouya M, Yang B, Tam F, McElcheran C, Graham S PLoS One. 2024; 19(12):e0316002.

PMID: 39693369 PMC: 11654958. DOI: 10.1371/journal.pone.0316002.