» Articles » PMID: 17161876

Development of an Integrated Cell Culture--real-time RT-PCR Assay for Detection of Reovirus in Biosolids

Overview
Journal J Virol Methods
Specialty Microbiology
Date 2006 Dec 13
PMID 17161876
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

The current method for viral detection in biosolids is a plaque assay, as specified by the EPA in the 40 CFR Part 503 rule. Development of an integrated cell culture-polymerase chain reaction (ICC-PCR) assay has allowed detection of viruses that are under-detected and undetected by the plaque assay. This study examined the efficiency of the ICC-PCR method to detect mammalian orthoreovirus, a virus typically under-detected in biosolids. Biosolid samples seeded with mammalian orthoreovirus type 1 (Lang) detected to 3 x 10(5) plaque forming units (pfu) with a plaque assay, 10(2)pfu equivalents with real-time RT-PCR and no incubation, and 10(8)pfu equivalents with real-time RT-PCR after 7 days incubation. More infectious virus was detected using ICC-real-time RT-PCR than a plaque assay. Twenty-four environmental samples from three locations around the United States did not plaque with the EPA method; however the ICC-PCR detected infectious reovirus in 13 of the samples. Raw biosolids samples accounted for 12 of the positive samples, and 1 positive was from an aerobically digested sample.

Citing Articles

The comparison of decay rates of infectious SARS-CoV-2 and viral RNA in environmental waters and wastewater.

Korajkic A, McMinn B, Pemberton A, Kelleher J, Ahmed W Sci Total Environ. 2024; 946:174379.

PMID: 38955270 PMC: 11290430. DOI: 10.1016/j.scitotenv.2024.174379.


Development of a rapid viability RT-PCR (RV-RT-PCR) method to detect infectious SARS-CoV-2 from swabs.

Shah S, Kane S, Elsheikh M, Alfaro T J Virol Methods. 2021; 297:114251.

PMID: 34380012 PMC: 8349479. DOI: 10.1016/j.jviromet.2021.114251.


Viruses in wastewater: occurrence, abundance and detection methods.

Corpuz M, Buonerba A, Vigliotta G, Zarra T, Ballesteros Jr F, Campiglia P Sci Total Environ. 2020; 745:140910.

PMID: 32758747 PMC: 7368910. DOI: 10.1016/j.scitotenv.2020.140910.


Low occurrence of Hepatitis A virus in water samples from an urban area of Southern Brazil.

Souza F, da Silva F, Staggemeier R, Rigotto C, Spilki F Rev Inst Med Trop Sao Paulo. 2018; 60:e69.

PMID: 30427404 PMC: 6223251. DOI: 10.1590/S1678-9946201860069.


Xenotransplantation panel for the detection of infectious agents in pigs.

Hartline C, Conner R, James S, Potter J, Gray E, Estrada J Xenotransplantation. 2018; 25(4):e12427.

PMID: 30264882 PMC: 6166664. DOI: 10.1111/xen.12427.