» Articles » PMID: 17125829

Long-term TEM Analysis of the Nanoleakage Patterns in Resin-dentin Interfaces Produced by Different Bonding Strategies

Overview
Journal Dent Mater
Specialty Dentistry
Date 2006 Nov 28
PMID 17125829
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The aim of this study was to evaluate the ability of etch-and-rinse and self-etching adhesive systems to prevent time- and water-induced nanoleakage in resin-dentin interfaces over a 6-month storage period.

Methods: Five commercial adhesives were tested, which comprise three different strategies of bonding resins to tooth hard tissues: one single-step self-etching adhesive (One-up Bond F (OB), Tokuyama); two two-step self-etching primers (Clearfil SE Bond (SE) and an antibacterial fluoride-containing system, Clearfil Protect Bond (CP), Kuraray Inc.); two two-step etch-and-rinse adhesives (Single Bond (SB), 3M ESPE and Prime&Bond NT (PB), Dentsply). Restored teeth were sectioned into 0.9 mm thick slabs and stored in water or mineral oil for 24 h, 3 or 6 months. A silver tracer solution was used to reveal nanometer-sized water-filled spaces and changes that occurred over time within resin-dentin interfaces. Characterization of interfaces was performed with the TEM.

Results: The two two-step self-etching primers showed little silver uptake during the 6-month experiment. Etch-and-rinse adhesives exhibited silver deposits predominantly within the hybrid layer (HL), which significantly increased for SB after water-storage. The one-step self-etching adhesive OB presented massive silver accumulation within the HL and water-trees protruding into the adhesive layer, which increased in size and quantity after water-storage. After storage in oil, reduced silver deposition was observed at the interfaces for all groups.

Significance: Different levels of water-induced nanoleakage were observed for the different bonding strategies. The two-step self-etching primers, especially the antibacterial fluoride-containing system CP, showed the least nanoleakage after 6 months of storage in water.

Citing Articles

Effect of phytic acid on bond strength and interfacial integrity of universal adhesive to deep dentin.

Attia A, Abo-Elezz A, Safy R Braz Dent J. 2022; 33(5):116-125.

PMID: 36287493 PMC: 9645176. DOI: 10.1590/0103-6440202204810.


Adhesion of multimode adhesives to enamel and dentin after one year of water storage.

Vermelho P, Reis A, Ambrosano G, Giannini M Clin Oral Investig. 2016; 21(5):1707-1715.

PMID: 27714528 DOI: 10.1007/s00784-016-1966-1.


The use of micro-CT with image segmentation to quantify leakage in dental restorations.

Carrera C, Lan C, Escobar-Sanabria D, Li Y, Rudney J, Aparicio C Dent Mater. 2015; 31(4):382-90.

PMID: 25649496 PMC: 4374050. DOI: 10.1016/j.dental.2015.01.002.


Resin-dentin bonding interface after photochemical surface treatment.

Tonami K, Sano K, Ichinose S, Araki K Photomed Laser Surg. 2015; 33(1):47-52.

PMID: 25555032 PMC: 4298159. DOI: 10.1089/pho.2014.3813.


Effects of solvent evaporation on water sorption/solubility and nanoleakage of adhesive systems.

Chimeli T, DAlpino P, Pereira P, Hilgert L, Di Hipolito V, Garcia F J Appl Oral Sci. 2014; 22(4):294-301.

PMID: 25141201 PMC: 4126825. DOI: 10.1590/1678-775720130653.