» Articles » PMID: 17073341

Acoustic Estimation of Thermal Distribution in the Vicinity of Femtosecond Laser-induced Optical Breakdown

Overview
Date 2006 Nov 1
PMID 17073341
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Laser-induced optical breakdown (LIOB), or photo-disruption, can generate individual microbubbles in tissues for biomedical applications. We have previously developed a co-localized high-frequency ultrasound system to detect and characterize these laser-induced microbubbles. Because ultrasound speed varies with temperature, this system can also be used to directly estimate thermal effects in the vicinity of photodisruption. In this study, individual bubbles (sizes 60-100 microm) were created at the bottom of a water tank using a 793-nm, 100-fs Ti:Sapphire laser pulsed at 250 kHz. During and after breakdown, pulse-echoes from the tank bottom in the region surrounding a bubble were recorded with a single-element 85-MHz ultrasonic transducer, and temperature-dependent pulse-echo displacements were calculated using phase-sensitive correlation tracking. These displacements were then fit to a finite-element heat transfer model to estimate the effective thermal distribution. Estimates were calculated for laser exposure times ranging from 6.25 to 312.5 ms (1600 to 78 000 laser pulses), at 1.5 and 4 J/cm2 fluences. Results suggest a minimal temperature increase (<1 degrees C) within 100 microm of a bubble created with <1600 laser pulses at 1.5 J/cm2 fluence. This implies that LIOB can be controlled to be thermally noninvasive in the bubble vicinity.

Citing Articles

Laser-Induced Plasmonic Nanobubbles and Microbubbles in Gold Nanorod Colloidal Solution.

Yu S, Tu C, Liaw J, Kuo M Nanomaterials (Basel). 2022; 12(7).

PMID: 35407272 PMC: 9000872. DOI: 10.3390/nano12071154.


Flexible integration of high-imaging-resolution and high-power arrays for ultrasound-induced thermal strain imaging (US-TSI).

Stephens D, Mahmoud A, Ding X, Lucero S, Dutta D, Yu F IEEE Trans Ultrason Ferroelectr Freq Control. 2013; 60(12):2645-56.

PMID: 24297029 PMC: 3857565. DOI: 10.1109/TUFFC.2013.2863.


Fast ultrasound beam prediction for linear and regular two-dimensional arrays.

Hlawitschka M, McGough R, Ferrara K, Kruse D IEEE Trans Ultrason Ferroelectr Freq Control. 2011; 58(9):2001-12.

PMID: 21937338 PMC: 3306819. DOI: 10.1109/TUFFC.2011.2044.


Structure of intracorneal femtosecond laser pulse effects in conical incision profiles.

Vossmerbaeumer U, Jonas J Graefes Arch Clin Exp Ophthalmol. 2008; 246(7):1017-20.

PMID: 18446357 DOI: 10.1007/s00417-008-0822-7.


Remote temperature estimation in intravascular photoacoustic imaging.

Sethuraman S, Aglyamov S, Smalling R, Emelianov S Ultrasound Med Biol. 2007; 34(2):299-308.

PMID: 17935861 PMC: 2267933. DOI: 10.1016/j.ultrasmedbio.2007.07.021.