» Articles » PMID: 17064275

Development of a Multiple Internal Control for Clinical Diagnostic Real-time Amplification Assays

Overview
Date 2006 Oct 27
PMID 17064275
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A major pitfall in most published genomic amplification methods for the detection and identification of human pathogens is that they do not include an internal amplification control in order to achieve an acceptable level of confidence for the absence of false-negative results. By applying composite primer technology, a single multiple internal amplification control DNA molecule was constructed to detect and quantify the hepatitis B virus, human polyomavirus, Epstein-Barr virus, Toxoplasma gondii and cytomegalovirus using real-time PCR. The multiple internal amplification control contains all forward and reverse primer binding regions targeted in the five distinct duplex PCRs, but with a unique probe hybridization site. Multiple internal amplification control detection sensitivity, assessed by Probit analysis, was 58 copies per PCR, associated with an extremely wide dynamic range (8 log(10) units). Moreover, in testing 614 patient samples, PCR inhibition occurred at a frequency of 0-8.8%. Similar multiple internal amplification controls for quantitative PCR-based assays could be designed to accommodate any infectious profiles in a particular institution as they are easy to make and inexpensive.

Citing Articles

Inhibition of polymerase chain reaction: Pathogen-specific controls are better than human gene amplification.

Roux G, Ravel C, Varlet-Marie E, Jendrowiak R, Bastien P, Sterkers Y PLoS One. 2019; 14(9):e0219276.

PMID: 31560697 PMC: 6764677. DOI: 10.1371/journal.pone.0219276.


Internal control for real-time polymerase chain reaction based on MS2 bacteriophage for RNA viruses diagnostics.

Zambenedetti M, Pavoni D, Dallabona A, Dominguez A, Poersch C, Fragoso S Mem Inst Oswaldo Cruz. 2017; 112(5):339-347.

PMID: 28403327 PMC: 5398160. DOI: 10.1590/0074-02760160380.


Development of a real time PCR assay for rapid detection of Vibrio parahaemolyticus from seafood.

Liu B, He X, Chen W, Yu S, Shi C, Zhou X Protein Cell. 2012; 3(3):204-12.

PMID: 22477699 PMC: 4875422. DOI: 10.1007/s13238-012-2017-6.


Validation of laboratory-developed molecular assays for infectious diseases.

Burd E Clin Microbiol Rev. 2010; 23(3):550-76.

PMID: 20610823 PMC: 2901657. DOI: 10.1128/CMR.00074-09.


Accurate quantification of microorganisms in PCR-inhibiting environmental DNA extracts by a novel internal amplification control approach using Biotrove OpenArrays.

van Doorn R, Klerks M, van Gent-Pelzer M, Speksnijder A, Kowalchuk G, Schoen C Appl Environ Microbiol. 2009; 75(22):7253-60.

PMID: 19801486 PMC: 2786501. DOI: 10.1128/AEM.00796-09.