Abstract

The purpose of this study was to determine the physical collection efficiency of commercially available filters for collecting airborne bacteria, viruses, and other particles in the 10-900 nm (nanometer) size range. Laboratory experiments with various polytetrafluoroethylene (PTFE), polycarbonate (PC) and gelatin filters in conjunction with Button Inhalable samplers and three-piece cassettes were undertaken. Both biological and non-biological test aerosols were used: Bacillus atrophaeus, MS2, polystyrene latex (PSL), and sodium chloride (NaCl). The B.atrophaeus endospores had an aerodynamic diameter of 900 nm, whereas MS2 virion particles ranged from 10 to 80 nm. Monodisperse 350 nm PSL particles were used as this size was believed to have the lowest filtration efficiency. NaCl solution (1% weight by volume) was used to create a polydisperse aerosol in the 10-600 nm range. The physical collection efficiency was determined by measuring particle concentrations size-selectively upstream and downstream of the filters. The PTFE and gelatin filters showed excellent collection efficiency (>93%) for all of the test particles. The PC filters showed lower collection efficiency for small particles especially <100 nm. Among the tested filters, the lowest collection efficiencies, 49 and 22%, were observed for 1 and 3-microm pore size PC filters at the particle sizes of 47 and 63 nm, respectively. The results indicate that the effect of filter material is more significant for the size range of single virions than for bacteria. The effect of filter loading was examined by exposing filters to mixtures of PSL particles, which aimed at mimicking typical indoor dust levels and size distributions. A 4-h loading did not cause significant change in the physical collection efficiency of the tested filters.

Citing Articles

Nanofibrous filters: A promising solution for the efficient capture of polydisperse viral aerosols.

Fadeev A, Crown K, Kinahan S, Lucero G, Salkovskiy Y Aerosol Sci Technol. 2025; 59(1):34-48.

PMID: 39991511 PMC: 11845214. DOI: 10.1080/02786826.2024.2421392.


Chemical Analysis of Deep-Lung Fluid Derived from Exhaled Breath Particles.

Kakeshpour T, Louis J, Walter P, Bax A Anal Chem. 2025; 97(7):4128-4136.

PMID: 39949307 PMC: 11859745. DOI: 10.1021/acs.analchem.4c06422.


Laboratory studies on the infectivity of human respiratory viruses: Experimental conditions, detections, and resistance to the atmospheric environment.

Hu Y, Peng S, Su B, Wang T, Lin J, Sun W Fundam Res. 2024; 4(3):471-483.

PMID: 38933192 PMC: 11197496. DOI: 10.1016/j.fmre.2023.12.017.


Advancements in Airborne Viral Nucleic Acid Detection with Wearable Devices.

Godin R, Hejazi S, Reuel N Adv Sens Res. 2024; 3(3).

PMID: 38764891 PMC: 11101210. DOI: 10.1002/adsr.202300061.


Mechanisms, Techniques and Devices of Airborne Virus Detection: A Review.

Chang Y, Wang Y, Li W, Wei Z, Tang S, Chen R Int J Environ Res Public Health. 2023; 20(8).

PMID: 37107752 PMC: 10138381. DOI: 10.3390/ijerph20085471.


References
1.
Burton N, Adhikari A, Grinshpun S, Hornung R, Reponen T . The effect of filter material on bioaerosol collection of Bacillus subtilis spores used as a Bacillus anthracis simulant. J Environ Monit. 2005; 7(5):475-80. DOI: 10.1039/b500056d. View

2.
Aizenberg V, Grinshpun S, Willeke K, Smith J, Baron P . Performance characteristics of the button personal inhalable aerosol sampler. AIHAJ. 2000; 61(3):398-404. DOI: 10.1080/15298660008984550. View

3.
Tseng C, Li C . Collection efficiencies of aerosol samplers for virus-containing aerosols. J Aerosol Sci. 2020; 36(5):593-607. PMC: 7118727. DOI: 10.1016/j.jaerosci.2004.12.004. View

4.
Smith L, Carroll K, Mottice S . Comparison of membrane filters for recovery of legionellae from water samples. Appl Environ Microbiol. 1993; 59(1):344-6. PMC: 202103. DOI: 10.1128/aem.59.1.344-346.1993. View

5.
Lee T, Grinshpun S, Martuzevicius D, Adhikari A, Crawford C, Luo J . Relationship between indoor and outdoor bio-aerosols collected with a button inhalable aerosol sampler in urban homes. Indoor Air. 2006; 16(1):37-47. PMC: 2233950. DOI: 10.1111/j.1600-0668.2005.00396.x. View