Multiplex Assay for Simultaneous Measurement of Antibodies to Multiple Plasmodium Falciparum Antigens

Overview
Date 2006 Oct 13
PMID 17035513
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

Antibodies to Plasmodium falciparum are classically measured using the enzyme-linked immunosorbent assay (ELISA). Although highly sensitive, this technique is labor-intensive when large numbers of samples must be screened against multiple antigens. The suspension array technology (SAT) might be an alterative to ELISA, as it allows measurement of antibodies against multiple antigens simultaneously with a small volume of sample. This study sought to adapt the new SAT multiplex system for measuring antibodies against nine malarial vaccine candidate antigens, including recombinant proteins from two variants of merozoite surface protein 1, two variants of apical merozoite antigen 1, erythrocyte binding antigen 175, merozoite surface protein 3, and peptides from the circumsporozoite protein, ring erythrocyte surface antigen, and liver-stage antigen 1. Various concentrations of the antigens were coupled to microspheres with different spectral addresses, and plasma samples from Cameroonian adults were screened by SAT in mono- and multiplex formats and by ELISA. Optimal amounts of protein required to perform the SAT assay were 10- to 100-fold less than that needed for ELISA. Excellent agreement was found between the single and multiplex formats (R > or = 0.96), even when two variants of the same antigen were used. The multiplex assay was rapid, reproducible, required less than 1 mul of plasma, and had a good correlation with ELISA. Thus, SAT provides an important new tool for studying the immune response to malaria rapidly and efficiently in large populations, even when the amount of plasma available is limited, e.g., in studies of neonates or finger-prick blood.

Citing Articles

Multiplex Assays for Analysis of Antibody Responses to South Asian and Malaria Infections.

Momoh E, Ghag S, White J, Mudeppa D, Rathod P Vaccines (Basel). 2024; 12(1).

PMID: 38276660 PMC: 10818873. DOI: 10.3390/vaccines12010001.


Analytical approaches for antimalarial antibody responses to confirm historical and recent malaria transmission: an example from the Philippines.

Macalinao M, Fornace K, Reyes R, Hall T, Bareng A, Adams J Lancet Reg Health West Pac. 2023; 37:100792.

PMID: 37693871 PMC: 10485684. DOI: 10.1016/j.lanwpc.2023.100792.


Are high avidity antibodies to Plasmodium falciparum antigens preferentially transferred across the placenta of premature and term babies?.

Kayatani A, Bobbili N, Megnekou R, Matsunaga M, Leke R, Taylor D Placenta. 2023; 140:11-19.

PMID: 37515848 PMC: 10528449. DOI: 10.1016/j.placenta.2023.07.011.


Transplacental transfer of total immunoglobulin G and antibodies to Plasmodium falciparum antigens between the 24th week of gestation and term.

Kayatani A, Leke R, Leke R, Fogako J, Taylor D Sci Rep. 2022; 12(1):18864.

PMID: 36344542 PMC: 9640577. DOI: 10.1038/s41598-022-21908-8.


Detecting asymptomatic carriage of Plasmodium falciparum in southern Ghana: utility of molecular and serological diagnostic tools.

Agbana H, Rogier E, Lo A, Abukari Z, Jones S, Gyan B Malar J. 2022; 21(1):57.

PMID: 35183178 PMC: 8858553. DOI: 10.1186/s12936-022-04078-w.


References
1.
Vignali D . Multiplexed particle-based flow cytometric assays. J Immunol Methods. 2000; 243(1-2):243-55. DOI: 10.1016/s0022-1759(00)00238-6. View

2.
Willman J, Hill H, Martins T, Jaskowski T, Ashwood E, Litwin C . Multiplex analysis of heterophil antibodies in patients with indeterminate HIV immunoassay results. Am J Clin Pathol. 2001; 115(5):764-9. DOI: 10.1309/3F13-739A-NA7F-NV3X. View

3.
Kellar K, Kalwar R, Dubois K, Crouse D, Chafin W, Kane B . Multiplexed fluorescent bead-based immunoassays for quantitation of human cytokines in serum and culture supernatants. Cytometry. 2001; 45(1):27-36. DOI: 10.1002/1097-0320(20010901)45:1<27::aid-cyto1141>3.0.co;2-i. View

4.
Nolan J, Sklar L . Suspension array technology: evolution of the flat-array paradigm. Trends Biotechnol. 2001; 20(1):9-12. DOI: 10.1016/s0167-7799(01)01844-3. View

5.
Mandy F, Nakamura T, Bergeron M, Sekiguchi K . Overview and application of suspension array technology. Clin Lab Med. 2002; 21(4):713-29, vii. View