Comparison of SPECT Aerosol Deposition Data with a Human Respiratory Tract Model

Overview
Journal J Aerosol Med
Date 2006 Oct 13
PMID 17034303
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

Three-dimensional (3D) radionuclide imaging provides detailed information on the distribution of inhaled aerosol material within the body. Analysis of the data can provide estimates of the deposition per airway generation. In this study, two different nebulizers have been used to deliver radiolabeled aerosols of different particle size to 12 human subjects. Medical imaging has been used to assess the deposition in the body. The deposition pattern has also been estimated using the International Commission on Radiological Protection (ICRP) empirical model and compared to values obtained by experiment. The results showed generally good agreement between model and experiment for both aerosols for the deposition in the extrathoracic and conducting airways. However, there were significant differences in the fate of the remainder of the aerosol between the amount deposited in the alveolar region and that exhaled. The inter-subject variability of deposition predicted by the model was significantly less than that measured, for all regions of the body. The model predicted quite well the differences in deposition distribution pattern between the two aerosols. In conclusion, this study has shown that the ICPR model of inhaled aerosol deposition shows areas of good agreement with results from experiment. However, there are also areas of disagreement, which may be explained by hygroscopic particle growth and individual variation in airway anatomy.

Citing Articles

Enhanced Optimal Parameter-Based Nebulizer Design for Flow Analysis of Fluticasone Propionate.

N V, Lokavarapu B AAPS PharmSciTech. 2023; 24(4):85.

PMID: 36949186 DOI: 10.1208/s12249-023-02548-1.


Assessment of the predictive capability of modelling and simulation to determine bioequivalence of inhaled drugs: A systematic review.

Rebello J, Brashier B, Shukla S Daru. 2022; 30(1):229-243.

PMID: 35094370 PMC: 9114201. DOI: 10.1007/s40199-021-00423-7.


Humidified and Heated Cascade Impactor for Aerosol Sizing.

Majoral C, Coates A, Le Pape A, Vecellio L Front Bioeng Biotechnol. 2020; 8:589782.

PMID: 33282850 PMC: 7691492. DOI: 10.3389/fbioe.2020.589782.


Use of computational fluid dynamics deposition modeling in respiratory drug delivery.

Longest P, Bass K, Dutta R, Rani V, Thomas M, El-Achwah A Expert Opin Drug Deliv. 2018; 16(1):7-26.

PMID: 30463458 PMC: 6529297. DOI: 10.1080/17425247.2019.1551875.


Validating Whole-Airway CFD Predictions of DPI Aerosol Deposition at Multiple Flow Rates.

Longest P, Tian G, Khajeh-Hosseini-Dalasm N, Hindle M J Aerosol Med Pulm Drug Deliv. 2016; 29(6):461-481.

PMID: 27082824 PMC: 5220557. DOI: 10.1089/jamp.2015.1281.