» Articles » PMID: 17011124

Simultaneous Preconcentration and Determination of Copper, Nickel, Cobalt and Lead Ions Content by Flame Atomic Absorption Spectrometry

Overview
Journal J Hazard Mater
Publisher Elsevier
Date 2006 Oct 3
PMID 17011124
Citations 55
Authors
Affiliations
Soon will be listed here.
Abstract

A sensitive and simple method for the simultaneous preconcentration of nutritionally important minerals in real samples has been reported. The method is based on the formation of metal complexes by 4,6-dihydroxy-2-mercaptopyrimidine (DHMP) loaded on activated carbon. The metals content on the complexes are then eluted using 5 mL 2M HNO(3) in acetone, which are detected by AAS at resonance line. In this procedure, minerals such as Cu, Ni, Pb and Co could be analyzed in one run by caring out the simultaneous separation and quantification of them. At optimum condition the response are linear over concentration range of 0.04-1.1 microg mL(-1) for Ni(2+) and 0.04-1.0 microg mL(-1) for Cu(2+), Pb(2+) and Co(2+). The detection limits of each element are expressed as the amount of analytes in ng mL(-1) giving a signal to noise ratio of 3 are equal to 3.5, 3.4, 2.9 and 8.4 for Ni(2+), Co(2+), Cu(2+) and Pb(2+). The sorption capacity was determined by saturating 0.5 g solid phase. The loading capacity are 0.54, 0.53, 0.63 and 0.45 mg g(-1) for Ni(2+), Co(2+), Cu(2+) and Pb(2+). The ability of method for repeatable recovery of trace ion are 99.0, 98.9, 99.2 and 98.8 with R.S.D. of 1.4, 1.3, 1.2 and 1.4 for Ni(2+), Co(2+), Cu(2+) and Pb(2+). The low detection limits of these elements in this technique make it a superior alternative to UV-vis and in several applications, also an alternative to ICP-MS techniques. The method has been successfully applied for these metals content evaluation in some real samples including natural water, leaves of spinach and cow liver.

Citing Articles

Clinical and mechanistic insights into biomedical application of Se-enriched probiotics and biogenic selenium nanoparticles.

Ataollahi F, Amirheidari B, Amirheidari Z, Ataollahi M Biotechnol Lett. 2025; 47(1):18.

PMID: 39826010 DOI: 10.1007/s10529-024-03559-z.


Green-Emitting AIEgen for Fluorescent Switch-Off Detection of Multi-Cations and Applications.

Patel D, Anand T, Jali B, Sahoo S J Fluoresc. 2025; .

PMID: 39804562 DOI: 10.1007/s10895-024-04102-z.


Low-cost portable sensor for rapid and sensitive detection of Pb ions using capacitance sensing integrated with microfluidic enrichment.

Amin N, Chen J, Cao Q, Qi H, Zhang J, He Q Mikrochim Acta. 2024; 191(11):718.

PMID: 39477888 DOI: 10.1007/s00604-024-06798-z.


Synthesis of the modified SBA-15 mesoporous silica with TAN ligand to preconcentrate and determine trace amounts of Ni (II) ions in water and wastewater samples.

Amouzad Mahdirajeh T, Mirabi A, Habibi Juybari M, Zafar Mehrabian R, Jalilian H Front Chem. 2024; 12:1410136.

PMID: 39439932 PMC: 11494652. DOI: 10.3389/fchem.2024.1410136.


Ultrasensitive Electrochemical Biosensors Based on Allosteric Transcription Factors (aTFs) for Pb Detection.

Yu N, Zhao C, Kang X, Zhang C, Zhang X, Li C Biosensors (Basel). 2024; 14(9).