» Articles » PMID: 17001575

The Role of Simeticone in Small-bowel Preparation for Capsule Endoscopy

Overview
Journal Endoscopy
Date 2006 Sep 27
PMID 17001575
Citations 22
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Study Aims: Capsule endoscopy is a new diagnostic method allowing painless visualization of the entire small bowel. However, there is as yet no standardized protocol for bowel preparation before the examination. The aim of this study was to assess the effectiveness of simeticone in reducing bowel gas bubbles in patients undergoing capsule endoscopy.

Patients And Methods: A randomized, prospective, and controlled study was conducted, including 56 patients, from March to October 2004. The patients were randomly allocated to groups receiving either simeticone or no simeticone, on the basis of a computer-generated random number table. Patients in the simeticone group (n = 28) received 300 mg simeticone for bowel preparation 20 min before capsule endoscopy, while patients in the non-simeticone group (n = 28) received no medication for bowel preparation. Two experienced endoscopists assessed and graded the visibility of the mucosa and intraluminal gas bubbles in a single-blinded fashion.

Results: The visibility of the mucosa in the proximal small bowel in patients who received preparation with simeticone was considered to be better, with fewer intraluminal bubbles, than in those without bowel preparation ( P < 0.025). Interobserver agreement was excellent ( R > or = 0.8, P < 0.05). No adverse effects of simeticone were observed.

Conclusions: Simeticone administration before capsule endoscopy improves the visualization of the mucosa in the proximal small intestine.

Citing Articles

Effect of simethicone for the management of early abdominal distension after laparoscopic cholecystectomy: a multicenter retrospective propensity score matching study.

Zhu Y, Li J, Gao J, Bai D, Yu Z, Jin S BMC Surg. 2024; 24(1):170.

PMID: 38811935 PMC: 11134702. DOI: 10.1186/s12893-024-02460-w.


Inter/Intra-Observer Agreement in Video-Capsule Endoscopy: Are We Getting It All Wrong? A Systematic Review and Meta-Analysis.

Cortegoso Valdivia P, Deding U, Bjorsum-Meyer T, Baatrup G, Fernandez-Urien I, Dray X Diagnostics (Basel). 2022; 12(10).

PMID: 36292089 PMC: 9600122. DOI: 10.3390/diagnostics12102400.


A randomized controlled trial of high volume simethicone to improve visualization during capsule endoscopy.

Sey M, Yan B, McDonald C, Segal D, Friedland J, Puka K PLoS One. 2021; 16(4):e0249490.

PMID: 33793636 PMC: 8016230. DOI: 10.1371/journal.pone.0249490.


Performance measures for small-bowel endoscopy: A European Society of Gastrointestinal Endoscopy (ESGE) Quality Improvement Initiative.

Spada C, McNamara D, Despott E, Adler S, Cash B, Fernandez-Urien I United European Gastroenterol J. 2019; 7(5):614-641.

PMID: 31210941 PMC: 6545716. DOI: 10.1177/2050640619850365.


Repetitive Position Change Improves Gastric Cleanliness for Magnetically Controlled Capsule Gastroscopy.

Wang Y, Pan J, Jiang X, Su X, Zhou W, Zou W Dig Dis Sci. 2018; 64(5):1297-1304.

PMID: 30560329 DOI: 10.1007/s10620-018-5415-7.