Automation of Sample Mounting for Macromolecular Crystallography

Overview
Specialty Chemistry
Date 2006 Sep 27
PMID 17001102
Citations 56
Authors
Affiliations
Soon will be listed here.
Abstract

A standard sample holder and vial for cryocooled macromolecular crystals has been defined for use with robotic sample changers. This SPINE standard sample holder is a modified version, with added features and specifications, of sample holders in common use. In particular, the SPINE standard meets the precision required for automatic sample exchange and includes a cap that is identified by a two-dimensional datamatrix code as well as an optional vial. At the ESRF, the sample holder standard is in use with the EMBL/ESRF/BM14 robotic sample changer (SC3) which is installed on eight beamlines. The SC3 can hold up to 50 crystals stored in five baskets. A datamatrix reader in the SC3 ensures safe management of the sample flow and facilitates fully automatic screening and characterization of samples. Tools for handling and transporting 50 samples in a dry shipping dewar have been developed. In addition to the SC3, the SPINE sample holder is currently compatible with a number of other robotic sample changers.

Citing Articles

CHiMP: deep-learning tools trained on protein crystallization micrographs to enable automation of experiments.

King O, Levik K, Sandy J, Basham M Acta Crystallogr D Struct Biol. 2024; 80(Pt 10):744-764.

PMID: 39361357 PMC: 11448919. DOI: 10.1107/S2059798324009276.


The High-Pressure Freezing Laboratory for Macromolecular Crystallography (HPMX), an ancillary tool for the macromolecular crystallography beamlines at the ESRF.

Carpentier P, van der Linden P, Mueller-Dieckmann C Acta Crystallogr D Struct Biol. 2024; 80(Pt 2):80-92.

PMID: 38265873 PMC: 10836400. DOI: 10.1107/S2059798323010707.


Anaerobic fixed-target serial crystallography using sandwiched silicon nitride membranes.

Bjelcic M, Sigfridsson Clauss K, Aurelius O, Milas M, Nan J, Ursby T Acta Crystallogr D Struct Biol. 2023; 79(Pt 11):1018-1025.

PMID: 37860963 PMC: 10619425. DOI: 10.1107/S205979832300880X.


Millisecond cryo-trapping by the spitrobot crystal plunger simplifies time-resolved crystallography.

Mehrabi P, Sung S, von Stetten D, Prester A, Hatton C, Kleine-Dopke S Nat Commun. 2023; 14(1):2365.

PMID: 37185266 PMC: 10130016. DOI: 10.1038/s41467-023-37834-w.


AMX - the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II.

Schneider D, Soares A, Lazo E, Kreitler D, Qian K, Fuchs M J Synchrotron Radiat. 2022; 29(Pt 6):1480-1494.

PMID: 36345756 PMC: 9641562. DOI: 10.1107/S1600577522009377.