» Articles » PMID: 16996865

Comparison of Coronary Minimal Lumen Area Quantification by Sixty-four-slice Computed Tomography Versus Intravascular Ultrasound for Intermediate Stenosis

Overview
Journal Am J Cardiol
Date 2006 Sep 26
PMID 16996865
Citations 10
Authors
Affiliations
Soon will be listed here.
Abstract

The present study assessed 64-slice computed tomographic accuracy to quantify minimal lumen area (MLA) and determine lesion severity in intermediate stenosis by angiography compared with intravascular ultrasound (IVUS). Sixty-four-slice computed tomography (CT) has been shown to be effective in coronary stenotic assessment by visual estimation compared with angiography. However, angiography is not an accurate gold standard for intermediate stenotic quantification compared with IVUS. Forty patients (54 lesions) with 30% to 70% coronary stenosis by angiography in a major coronary branch were included. All patients underwent quantitative angiography, retrospective electrocardiographically gated 64-slice CT (Siemens), and IVUS (40-MHz Atlantis; Boston Scientific). MLA was manually traced by 2 blinded and independent operators on 64-slice computed tomographic cross-sectional reconstruction and compared with IVUS MLA. A lesion was considered significant if the MLA was <or=6 mm(2) for the left main coronary artery and <or=4 mm(2) for another epicardial vessel with CT and IVUS. The correlation between IVUS MLA and computed tomographic MLA was r = 0.88 (p <0.001). Interobserver variabilities (mean +/- SD) were 1.2 mm(2) for CT and 1.1 mm(2) for CT versus IVUS. Bland-Altman analysis showed a 95% confidence interval of -42% to +44% for computed tomographic measurement using IVUS as a reference. Sensitivity, specificity, accuracy, and Cohen's kappa coefficient for significant lesion classification using CT were 87%, 72%, 80%, and 0.6, respectively (p <0.0001). In conclusion, when using MLA, 64-slice CT was able to quantify coronary stenosis with good correlation compared with IVUS and determine lesion severity in patients with intermediate lesions by angiography.

Citing Articles

The Impact of Nitroglycerin on the Evaluation of Coronary Stenosis in Coronary-CT: Preliminary Study in 131 Patients.

DErrico F, Ricci F, Luciano A, Sbordone F, Laudazi M, Mecchia D J Clin Med. 2023; 12(16).

PMID: 37629336 PMC: 10455480. DOI: 10.3390/jcm12165296.


Reliability of coronary computed tomography angiography in acute coronary syndrome in an emergency setting.

Ternovoy S, Ustyuzhanin D, Shariya M, Shabanova M, Gaman S, Serova N Heliyon. 2021; 7(2):e06075.

PMID: 33553774 PMC: 7856469. DOI: 10.1016/j.heliyon.2021.e06075.


Impact of an intra-cycle motion correction algorithm on overall evaluability and diagnostic accuracy of computed tomography coronary angiography.

Pontone G, Andreini D, Bertella E, Baggiano A, Mushtaq S, Loguercio M Eur Radiol. 2015; 26(1):147-56.

PMID: 25953001 DOI: 10.1007/s00330-015-3793-1.


Lumen and calcium characteristics within calcified coronary lesions. Comparison of computed tomography coronary angiography versus intravascular ultrasound.

Noll D, Kruk M, Pregowski J, Kaczmarska E, Kryczka K, Pracon R Postepy Kardiol Interwencyjnej. 2014; 9(1):1-8.

PMID: 24570686 PMC: 3915947. DOI: 10.5114/pwki.2013.34022.


Diagnostic value of coronary CT angiography in comparison with invasive coronary angiography and intravascular ultrasound in patients with intermediate coronary artery stenosis: results from the prospective multicentre FIGURE-OUT (Functional Imaging....

Doh J, Koo B, Nam C, Kim J, Min J, Nakazato R Eur Heart J Cardiovasc Imaging. 2014; 15(8):870-7.

PMID: 24513881 PMC: 4110885. DOI: 10.1093/ehjci/jeu009.