» Articles » PMID: 16950932

The Evolution of the CEREC System

Overview
Journal J Am Dent Assoc
Publisher Elsevier
Specialty Dentistry
Date 2006 Sep 5
PMID 16950932
Citations 62
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Overview: Early in 1980, the author anticipated the attraction of restoring posterior teeth with tooth-colored material. He conducted studies and developed the clinical concept of bonded ceramic inlays, at the same time raising the issue of the fast fabrication of the ceramic restorations. The author developed plans for in-office computer-aided design/computer-aided manufacturing (CAD/CAM) fabrication of ceramic restorations specifically to enable the dentist to complete one or multiple ceramic restorations chairside, in a single appointment. The initial concept comprised a small mobile CAD/CAM unit integrating a computer, keyboard, trackball, foot pedal and optoelectronic mouth camera as input devices, a monitor and a machining compartment. CEREC 3 (Sirona Dental Systems GmbH, Bensheim, Germany) divided the system into an acquisition/design unit and a separate machining unit. Three-dimensional software makes the handling illustrative and easy both in the office and in the laboratory.

Conclusions: It appears that the CEREC CAD/CAM concept is becoming a significant part of dentistry.

Clinical Implications: Sound knowledge of adhesive bonding and diligent planning are essential for the successful integration of CAD/CAM into clinical dental offices.

Citing Articles

Accuracy of intraoral scanners in maxillary multiple restorations: An study.

Aung H, Linn T, Lee W, Chao J, Teng N, Renn T J Dent Sci. 2025; 19(Suppl 2):S116-S121.

PMID: 39807255 PMC: 11725155. DOI: 10.1016/j.jds.2024.07.016.


An In Vivo Comparison of Trueness and Precision of Two Novel Methods for Improving Edentulous Full Arch Implant Scanning Accuracy: A Pilot Study.

Nulty A Dent J (Basel). 2024; 12(11).

PMID: 39590417 PMC: 11592884. DOI: 10.3390/dj12110367.


Flexural Strength of Modern CAD/CAM Restoratives After Artificial Aging.

Melc T, Attin T, Eyuboglu T, Ozcan M Materials (Basel). 2024; 17(21).

PMID: 39517453 PMC: 11547040. DOI: 10.3390/ma17215178.


Clinical assessment of monolithic zirconia crowns fabricated using an intraoral scanner.

Eftekhar Ashtiani R, Khanlar L, Ghoveizi R, Beyabanaki E J Dent Res Dent Clin Dent Prospects. 2024; 18(3):219-224.

PMID: 39386129 PMC: 11459080. DOI: 10.34172/joddd.41070.


Knowledge structure and research hotspots on digital scanning for implant-supported complete-arch prosthesis: A bibliometric analysis.

Gao Y, Zhao M, Xia S, Sa Y Heliyon. 2024; 10(17):e36782.

PMID: 39286169 PMC: 11402722. DOI: 10.1016/j.heliyon.2024.e36782.