Effect of Bladder Volume on Measured Intravesical Pressure: a Prospective Cohort Study

Overview
Journal Crit Care
Specialty Critical Care
Date 2006 Aug 29
PMID 16934130
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Correct bedside measurement of intra-abdominal pressure (IAP) is important. The bladder method is considered as the gold standard for indirect IAP measurement, but the instillation volumes reported in the literature vary substantially. The aim of this study was to evaluate the effect of instillation volume on intra-bladder pressure (IBP) as an estimation for IAP in critically ill patients.

Methods: In this prospective cohort study in 13 sedated and mechanically ventilated patients, we used a revised closed system repeated measurement technique for measurement of IBP. After the system was flushed, IBP was measured with 25 ml increments up to 300 ml. The absolute bias for each volume was calculated as IBP at a given volume minus IBP at zero volume.

Results: In total, 30 measurement sets were performed (mean 2.3 per patient). The median IBP at 25 ml was already significantly higher than IBP at zero volume (7.5 versus 6 mmHg). There was no correlation between IBP at zero volume and absolute IBP bias at any bladder volume. Median absolute IBP bias was 1.5 mmHg at 50 ml; 2.5 mmHg at 100 ml; 5.5 mmHg at 150 ml; and up to 11 mmHg at 300 ml.

Conclusion: Larger instillation volumes than the usually recommended 50 ml to estimate IAP by bladder pressure may cause clinically relevant overestimation of IAP. Small volumes to a maximum of 25 ml, enough to create a fluid column and to remove air, may be sufficient.

Citing Articles

Differential Effects of Intra-Abdominal Hypertension and ARDS on Respiratory Mechanics in a Porcine Model.

Seybold B, Deutsch A, Deutsch B, Simeliunas E, Weigand M, Fiedler-Kalenka M Medicina (Kaunas). 2024; 60(6).

PMID: 38929460 PMC: 11205316. DOI: 10.3390/medicina60060843.


Impact of Different Positive End-Expiratory Pressures on Lung Mechanics in the Setting of Moderately Elevated Intra-Abdominal Pressure and Acute Lung Injury in a Porcine Model.

Fiedler M, Simeliunas E, Deutsch B, Diktanaite D, Harms A, Brune M J Clin Med. 2021; 10(2).

PMID: 33467666 PMC: 7830768. DOI: 10.3390/jcm10020306.


Prospective Observational Study to Evaluate the Effect of Different Levels of Positive End-Expiratory Pressure on Lung Mechanics in Patients with and without Acute Respiratory Distress Syndrome.

Fiedler M, Diktanaite D, Simeliunas E, Pilz M, Kalenka A J Clin Med. 2020; 9(8).

PMID: 32751791 PMC: 7463691. DOI: 10.3390/jcm9082446.


Effect of moderate elevated intra-abdominal pressure on lung mechanics and histological lung injury at different positive end-expiratory pressures.

Fiedler M, Deutsch B, Simeliunas E, Diktanaite D, Harms A, Brune M PLoS One. 2020; 15(4):e0230830.

PMID: 32294090 PMC: 7159202. DOI: 10.1371/journal.pone.0230830.


Intrabladder pressure as predictor of intra-abdominal pressure in horses.

de Paula V, Canola P, Rivera G, Z Filho D, Amaral G, Ferraz G PLoS One. 2019; 14(10):e0223705.

PMID: 31600317 PMC: 6786750. DOI: 10.1371/journal.pone.0223705.


References
1.
Fusco M, Martin R, Chang M . Estimation of intra-abdominal pressure by bladder pressure measurement: validity and methodology. J Trauma. 2001; 50(2):297-302. DOI: 10.1097/00005373-200102000-00016. View

2.
Kershen R, Azadzoi K, Siroky M . Blood flow, pressure and compliance in the male human bladder. J Urol. 2002; 168(1):121-5. View

3.
Biancofiore G, Bindi M, Romanelli A, Boldrini A, Consani G, Bisa M . Intra-abdominal pressure monitoring in liver transplant recipients: a prospective study. Intensive Care Med. 2003; 29(1):30-6. DOI: 10.1007/s00134-002-1552-7. View

4.
Balogh Z, McKinley B, Holcomb J, Miller C, Cocanour C, Kozar R . Both primary and secondary abdominal compartment syndrome can be predicted early and are harbingers of multiple organ failure. J Trauma. 2003; 54(5):848-59; discussion 859-61. DOI: 10.1097/01.TA.0000070166.29649.F3. View

5.
De Waele J, Pletinckx P, Blot S, Hoste E . Saline volume in transvesical intra-abdominal pressure measurement: enough is enough. Intensive Care Med. 2006; 32(3):455-9. DOI: 10.1007/s00134-005-0062-9. View