» Articles » PMID: 16897556

Leachate Characterization and Assessment of Groundwater Pollution Near Municipal Solid Waste Landfill Site

Overview
Publisher Springer
Date 2006 Aug 10
PMID 16897556
Citations 49
Authors
Affiliations
Soon will be listed here.
Abstract

Leachate and groundwater samples were collected from Gazipur landfill-site and its adjacent area to study the possible impact of leachate percolation on groundwater quality. Concentration of various physico-chemical parameters including heavy metal (Cd, Cr, Cu, Fe, Ni, Pb and Zn) and microbiological parameters (total coliform (TC) and faecal coliform (FC)) were determined in groundwater and leachate samples. The moderately high concentrations of Cl-, NO3(-), SO4(2-), NH4(+), Phenol, Fe, Zn and COD in groundwater, likely indicate that groundwater quality is being significantly affected by leachate percolation. Further they proved to be as tracers for groundwater contamination. The effect of depth and distance of the well from the pollution source was also investigated. The presence of TC and FC in groundwater warns for the groundwater quality and thus renders the associated aquifer unreliable for domestic water supply and other uses. Although some remedial measures are suggested to reduce further groundwater contamination via leachate percolation, the present study demand for the proper management of waste in Delhi.

Citing Articles

Comparing roles of multiple contamination indicators in tracing groundwater pollution nearby a typical municipal solid waste (MSW) landfill.

Meng J, Xiao G, Qi M, Han X, Gou Q, Hao X Heliyon. 2024; 10(16):e35601.

PMID: 39220911 PMC: 11363857. DOI: 10.1016/j.heliyon.2024.e35601.


Identification of prevalent leachate percolation of municipal solid waste landfill: a case study in India.

Alam P, Khan A, Islam R, Sabi E, Khan N, Zargar T Sci Rep. 2024; 14(1):8910.

PMID: 38632259 PMC: 11024205. DOI: 10.1038/s41598-024-58693-5.


Relationships between per- and polyfluoroalkyl substances (PFAS) and physical-chemical parameters in aqueous landfill samples.

Zhang H, Chen Y, Liu Y, Bowden J, Tolaymat T, Townsend T Chemosphere. 2023; 329:138541.

PMID: 36996915 PMC: 10680781. DOI: 10.1016/j.chemosphere.2023.138541.


Concentration of heavy metals in leachate, soil, and plants in Tehran's landfill: Investigation of the effect of landfill age on the intensity of pollution.

Hosseini Beinabaj S, Heydariyan H, Mohammad Aleii H, Hosseinzadeh A Heliyon. 2023; 9(1):e13017.

PMID: 36747943 PMC: 9898684. DOI: 10.1016/j.heliyon.2023.e13017.


Waste-Derived Copper-Lead Electrocatalysts for CO Reduction.

Yang S, An H, Anastasiadou D, Xu W, Wu L, Wang H ChemCatChem. 2023; 14(18):e202200754.

PMID: 36588984 PMC: 9796115. DOI: 10.1002/cctc.202200754.


References
1.
Loizidou M, Kapetanios E . Effect of leachate from landfills on underground water quality. Sci Total Environ. 1993; 128(1):69-81. DOI: 10.1016/0048-9697(93)90180-e. View

2.
Ravindra K, Ameena , Meenakshi , Monika , Rani , Kaushik A . Seasonal variations in physico-chemical characteristics of River Yamuna in Haryana and its ecological best-designated use. J Environ Monit. 2003; 5(3):419-26. DOI: 10.1039/b301723k. View

3.
Ravindra K, Garg V . Distribution of fluoride in groundwater and its suitability assessment for drinking purpose. Int J Environ Health Res. 2006; 16(2):163-6. DOI: 10.1080/09603120500538283. View

4.
Mor S, De Visscher A, Ravindra K, Dahiya R, Chandra A, van Cleemput O . Induction of enhanced methane oxidation in compost: temperature and moisture response. Waste Manag. 2006; 26(4):381-8. DOI: 10.1016/j.wasman.2005.11.005. View

5.
De Rosa E, Rubel D, Tudino M, Viale A, Lombardo R . The leachate composition of an old waste dump connected to groundwater: Influence of the reclamation works. Environ Monit Assess. 2013; 40(3):239-52. DOI: 10.1007/BF00398869. View