» Articles » PMID: 16770526

Baroreflex Sensitivity Measured by Spectral and Sequence Analysis in Cerebrovascular Disease : Methodological Considerations

Overview
Journal Clin Auton Res
Date 2006 Jun 14
PMID 16770526
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

Baroreflex sensitivity (BRS) is impaired and of prognostic value in cerebrovascular disease. However, no studies to date have been published on the reproducibility of current methods of measuring BRS in this group. The reproducibility of sequence and spectral analysis methods were therefore assessed in subjects with cerebrovascular disease. A total of 14 subjects were assessed on 2 separate occasions at least 2 weeks apart, and beat-to-beat blood pressure (BP) and ECG trace were recorded for three 5-minute periods. These traces were then analyzed by spectral analysis using Fast Fourier Transform and sequence analysis. Reproducibility was calculated as the coefficient of variation (CV) and reproducibility coefficient (RC). There were no significant differences in heart rate, BP or BRS derived by either method between visits. Reproducibility was CV 22.2%, RC 6.04 ms/mmHg with spectral analysis, and CV 26.3%, RC 7.48 ms/mmHg for sequence analysis. There was close agreement between sequence and spectral derived BRS (r = 0.90). We have demonstrated that the use of spectral and sequence analysis to measure BRS is reproducible in subjects with cerebrovascular disease. These techniques are suitable for follow-up and intervention studies of BRS in this patient group.

Citing Articles

Cardiac autonomic function and cognitive performance in patients with atrial fibrillation.

Hammerle P, Aeschbacher S, Springer A, Eken C, Coslovsky M, Dutilh G Clin Res Cardiol. 2021; 111(1):60-69.

PMID: 34156525 PMC: 8766386. DOI: 10.1007/s00392-021-01900-4.


Association of Heart Rate Variability With Cognitive Performance: The Multi-Ethnic Study of Atherosclerosis.

Schaich C, Malaver D, Chen H, Shaltout H, Zeki Al Hazzouri A, Herrington D J Am Heart Assoc. 2020; 9(7):e013827.

PMID: 32200711 PMC: 7428623. DOI: 10.1161/JAHA.119.013827.


The Stability and Repeatability of Spontaneous Sympathetic Baroreflex Sensitivity in Healthy Young Individuals.

Hissen S, El Sayed K, Macefield V, Brown R, Taylor C Front Neurosci. 2018; 12:403.

PMID: 29962929 PMC: 6010576. DOI: 10.3389/fnins.2018.00403.


Restoring Sinus Rhythm Improves Baroreflex Function in Patients With Persistent Atrial Fibrillation.

Field M, Wasmund S, Page R, Hamdan M J Am Heart Assoc. 2016; 5(2).

PMID: 26908410 PMC: 4802450. DOI: 10.1161/JAHA.115.002997.


Shortening baroreflex delay in hypertrophic cardiomyopathy patients -- an unknown effect of β-blockers.

Katarzynska-Szymanska A, Ochotny R, Oko-Sarnowska Z, Wachowiak-Baszynska H, Krauze T, Piskorski J Br J Clin Pharmacol. 2012; 75(6):1516-24.

PMID: 23126403 PMC: 3690110. DOI: 10.1111/bcp.12027.


References
1.
Bland J, Altman D . Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; 1(8476):307-10. View

2.
Robbe H, Mulder L, Ruddel H, Langewitz W, Veldman J, Mulder G . Assessment of baroreceptor reflex sensitivity by means of spectral analysis. Hypertension. 1987; 10(5):538-43. DOI: 10.1161/01.hyp.10.5.538. View

3.
Colombo R, Mazzuero G, Spinatonda G, Lanfranchi P, Giannuzzi P, Ponikowski P . Comparison between spectral analysis and the phenylephrine method for the assessment of baroreflex sensitivity in chronic heart failure. Clin Sci (Lond). 1999; 97(4):503-13. View

4.
Pitzalis M, Mastropasqua F, Passantino A, Massari F, Ligurgo L, Forleo C . Comparison between noninvasive indices of baroreceptor sensitivity and the phenylephrine method in post-myocardial infarction patients. Circulation. 1998; 97(14):1362-7. DOI: 10.1161/01.cir.97.14.1362. View

5.
Oppenheimer S . Vasculocentricity versus cerebrocentricity: what stroke-related baroreceptor reflex sensitivity changes might be telling us. Stroke. 2003; 34(3):705-12. DOI: 10.1161/01.STR.0000058484.99234.D0. View