Theatre Over-shoes Do Not Reduce Operating Theatre Floor Bacterial Counts
Overview
Infectious Diseases
Affiliations
Occasional staff or visitors to operating theatres are usually requested to don over-shoes as this is perceived to reduce bacterial floor colony counts. However, this entails some expense and considerable inconvenience. Using disposable surface contact plates floor bacterial counts were measured four times a day at five different sites during the 5 normal working days of one 2-week period in a general operating theatre when over-shoes were worn and one 2-week period when over-shoes were not worn. There was no significant difference in the mean bacterial floor colony counts between the two periods according to sampling times or sites. As in Intensive Therapy units, over-shoes should no longer be used in general operating theatres.
Impact of Protective Footwear on Floor and Air Contamination of Intensive Care Units.
Gupta A, Anand A, Chumber S, Sashindran V, Patrikar S Med J Armed Forces India. 2016; 63(4):334-6.
PMID: 27408043 PMC: 4921992. DOI: 10.1016/S0377-1237(07)80009-8.
Ali Z, Qadeer A, Akhtar A Pak J Med Sci. 2014; 30(2):272-5.
PMID: 24772125 PMC: 3998992.
Effectiveness of shoe covers for bioexclusion within an animal facility.
Hickman-Davis J, Nicolaus M, Petty J, Harrison D, Bergdall V J Am Assoc Lab Anim Sci. 2012; 51(2):181-8.
PMID: 22776118 PMC: 3314521.
Microbial load and decontamination in the theatre suite.
Cairns S, Hegarty E Ann R Coll Surg Engl. 2008; 90(8):710.
PMID: 18990290 PMC: 2727837. DOI: 10.1308/003588408x321819.
Infection control in anaesthesia.
Anaesthesia. 2008; 63(9):1027-36.
PMID: 18699890 PMC: 2773534. DOI: 10.1111/j.1365-2044.2008.05657.x.