» Articles » PMID: 16645355

Aortic Dilatation in Patients with Bicuspid Aortic Valve

Overview
Date 2006 Apr 29
PMID 16645355
Citations 20
Authors
Affiliations
Soon will be listed here.
Abstract

The association of a bicuspid aortic valve (BAV) with abnormalities of the proximal thoracic aorta, including dilatation, aneurysm and dissection, has been previously described, leading to the hypothesis of a common underlying developmental defect involving the aortic valve and the aortic wall. Consequently, any patient with BAV should receive a careful assessment not only of the valve function, but also of the aortic root and the ascending aorta. Dilatation of the proximal thoracic aorta is a common finding in patients with BAV and is believed to be related to aortic rupture and dissection. Because progressive dilatation can occur, careful long-term surveillance of the aortic dimensions is required. Prophylactic surgical repair of the dilated aorta should be recommended more aggressively for patients with BAV than for those with a tricuspid aortic valve. However, the optimal timing of aortic surgery in BAV patients remains uncertain because of the limited data available on the natural history of asymptomatic aortic dilatation.

Citing Articles

Changes in inflammation and oxidative stress signalling pathways in coarcted aorta triggered by bicuspid aortic valve and growth in young children.

Skeffington K, Bond A, Bigotti M, AbdulGhani S, Iacobazzi D, Kang S Exp Ther Med. 2020; 20(5):48.

PMID: 32973936 PMC: 7506967. DOI: 10.3892/etm.2020.9171.


Disturbed nitric oxide signalling gives rise to congenital bicuspid aortic valve and aortopathy.

Peterson J, Wisse L, Wirokromo V, van Herwaarden T, Smits A, Gittenberger-de Groot A Dis Model Mech. 2020; 13(9).

PMID: 32801116 PMC: 7541347. DOI: 10.1242/dmm.044990.


Plasma Metabolomic Profiling Associates Bicuspid Aortic Valve Disease and Ascending Aortic Dilation with a Decrease in Antioxidant Capacity.

Martinez-Micaelo N, Ligero C, Antequera-Gonzalez B, Junza A, Yanes O, Alegret J J Clin Med. 2020; 9(7).

PMID: 32668689 PMC: 7408840. DOI: 10.3390/jcm9072215.


Aortic stiffness in aortic stenosis assessed by cardiovascular MRI: a comparison between bicuspid and tricuspid valves.

Singh A, Horsfield M, Bekele S, Greenwood J, Dawson D, Berry C Eur Radiol. 2018; 29(5):2340-2349.

PMID: 30488106 PMC: 6443917. DOI: 10.1007/s00330-018-5775-6.


Bicuspid Aortic Valve Registry of the Italian Society of Echocardiography and Cardiovascular Imaging (REgistro della valvola aortica bicuspide della società italiana di ECocardiografia e CArdiovascular imaging): Rationale and Study Design.

Citro R, Cecconi M, La Carrubba S, Bossone E, Antonini-Canterin F, Nistri S J Cardiovasc Echogr. 2018; 28(2):78-89.

PMID: 29911003 PMC: 5989554. DOI: 10.4103/jcecho.jcecho_5_18.