» Articles » PMID: 16643012

Universal Response in Liquid Chromatography Using Charged Aerosol Detection

Overview
Journal Anal Chem
Specialty Chemistry
Date 2006 Apr 29
PMID 16643012
Citations 16
Authors
Affiliations
Soon will be listed here.
Abstract

A new, empirical approach is introduced to correct for the varying response of aerosol-based detectors with the varying composition of the mobile phase during gradient elution in HPLC. A Corona charged aerosol detector was used in the experiments. The detector is characterized by a nearly universal response at a given, constant mobile-phase composition for sufficiently nonvolatile analytes. A second pump was used to deliver an exactly inverse gradient compared to the analytical HPLC system, and both flows were mixed in a tee piece before introduction to the Corona detector. The approach proposed made it possible to extend the universal response from isocratic to gradient elution conditions in HPLC, vastly improving the usefulness of this detection technique. The constant response of the detector obtained in this way was first demonstrated in flow injection analysis. Very similar calibration curves were obtained for six sulfonamide drugs after mobile-phase compensation. The approach was also applied to gradient elution with excellent results. The data were characterized by good precision ranging from 4% RSD at 10 mg/L to 1.6% RSD at 780 mg/L. The average limit of detection with a 2-microL injection was 0.5 mg/L, corresponding to 1 ng injected on the column. The approach proposed allows quantification of unknown compounds, e.g., in pharmaceutical mixtures. Measurement of analytes at a relative concentration of 0.05% versus the main component is demonstrated.

Citing Articles

Combined Quantification and Characterization of Dissolved Organic Matter by Liquid Chromatography-Mass Spectrometry Using Charged Aerosol Detection.

Felgate S, Jakobsson E, Balderrama Subieta A, Tranvik L, Hawkes J J Am Soc Mass Spectrom. 2024; 35(12):2910-2917.

PMID: 39367863 PMC: 11622222. DOI: 10.1021/jasms.4c00255.


Mass Balance in Pharmaceutical Stress Testing: A Review of Principles and Practical Applications.

Marden S, Campbell J, Adams N, Coelho R, Foti C, Franca J AAPS J. 2024; 26(5):96.

PMID: 39174806 DOI: 10.1208/s12248-024-00961-3.


Ultra high efficiency/low pressure supercritical fluid chromatography (UHE/LP-SFC) for triglyceride analysis: Identification, quantification, and classification of vegetable oils.

Lesellier E, Latos A, West C Anal Sci Adv. 2024; 2(1-2):33-42.

PMID: 38715743 PMC: 10989644. DOI: 10.1002/ansa.202000156.


Automated Composition Assessment of Natural Extracts: Untargeted Mass Spectrometry-Based Metabolite Profiling Integrating Semiquantitative Detection.

Rutz A, Wolfender J J Agric Food Chem. 2023; 71(46):18010-18023.

PMID: 37949451 PMC: 10683005. DOI: 10.1021/acs.jafc.3c03099.


Identification and quantification of biosurfactants produced by the marine bacterium Alcanivorax borkumensis by hyphenated techniques.

Lipphardt A, Karmainski T, Blank L, Hayen H, Tiso T Anal Bioanal Chem. 2023; 415(29-30):7067-7084.

PMID: 37819435 PMC: 10684412. DOI: 10.1007/s00216-023-04972-5.