Detecting the Limits of Bronchial Closure Methods in an Animal Model

Overview
Date 2006 Apr 28
PMID 16639682
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Bronchopleural fistula is a serious complication of major lung resections that may lead to mortality. An experimental animal model was designed to find out the safest bronchial closure method by comparing leakage rates under pressure.

Methods: The tracheobronchial trees of 50 freshly dead sheep were prepared for either manual closure or closure with a stapler. After left pneumonectomy, the specimens were divided into five groups (n = 10); 3/0 Premilene suture was used with two "u" sutures + interrupted sutures in Group I; in Group II, 3/0 Premilene sutures with continuous horizontal mattress + over-over continuous sutures were used. In Group III and IV the same techniques were used with 3/0 Vicryl. A stapler was used in Group V. Specimens were intubated with an endotracheal tube, connected to a sphygmomanometer, and subsequently positioned under water. The pressure level at which we detected air bubbles indicated the limits of the technique.

Results: The median leakage pressure resistance was significantly lower in Group III (135 mm Hg) ( P = 0.001). The best results were achieved by using the continuous horizontal mattress + over-over continuous suture technique. No statistical significance difference was found between the stapler group, Groups I, II, and IV in terms of median leakage pressures.

Conclusions: This trial suggests that manual suture closure using an appropriate technique and monofilament materials is as safe as the stapler.