» Articles » PMID: 16554216

Comparative Study of Torsional and Bending Properties for Six Models of Nickel-titanium Root Canal Instruments with Different Cross-sections

Overview
Journal J Endod
Publisher Elsevier
Specialty Dentistry
Date 2006 Mar 24
PMID 16554216
Citations 45
Authors
Affiliations
Soon will be listed here.
Abstract

This study investigated the influence of cross-section profile on the mechanical behaviors of six commercial nickel-titanium (NiTi) root canal instruments using the finite element method. The nonlinear mechanical characteristics of the NiTi alloy were taken into account. The six root canal instruments studied were ProTaper, Hero642, Mtwo, ProFile, Quantec, and NiTiflex. Mathematical models for these instruments were constructed and their performances were analyzed under equal torque conditions. The ProTaper and Hero642 models achieved the lowest stress levels that made them the most torque-resistant while the NiTiflex model was the poorest. The maximum stress value and the stress distribution in a model were found strongly influenced by the cross-section profile. Factors affecting the stress distribution include the cross-sectional inertia, depth of the flute, area of the inner core, radial land, and peripheral surface ground. As the area of the inner core of the cross-section increased, the model was more torque-resistant.

Citing Articles

The Biomechanics of Nickel Titanium Instrument Fracture in Root Canal Therapy: A Narrative Review.

Ohri K, Chien P, Peters O Materials (Basel). 2025; 17(24.

PMID: 39769746 PMC: 11678187. DOI: 10.3390/ma17246147.


Predictive factors in the retrieval of endodontic instruments: the relationship between the fragment length and location.

Portigliatti R, Consoli Lizzi E, Rodriguez P Restor Dent Endod. 2024; 49(4):e35.

PMID: 39649534 PMC: 11621310. DOI: 10.5395/rde.2024.49.e35.


Surface Coating of Nickel-Titanium (Ni-Ti) Pediatric Rotary File Using Graphene Oxide: A Scanning Electron Microscopy Analysis.

Panja K, A V, N V, Ramar K Cureus. 2024; 16(8):e66632.

PMID: 39258062 PMC: 11386944. DOI: 10.7759/cureus.66632.


Effect of simulated clinical use and sterilization on the cyclic fatigue resistance of nickel titanium files.

Alajemi M, AbuMostafa A PeerJ. 2024; 12:e17418.

PMID: 38799069 PMC: 11128215. DOI: 10.7717/peerj.17418.


Comparative evaluation of cyclic fatigue resistance of thermomechanically treated NiTi rotary instruments in simulated curved canals with two different radii of curvature: An Study.

Hamid T, Malik A, Kumar A, Anjum S J Conserv Dent Endod. 2024; 27(4):393-399.

PMID: 38779209 PMC: 11108414. DOI: 10.4103/JCDE.JCDE_32_24.