» Articles » PMID: 16541845

Occlusion, Sternocleidomastoid Muscle Activity, and Body Sway: a Pilot Study in Male Astronauts

Overview
Journal Cranio
Specialty Dentistry
Date 2006 Mar 18
PMID 16541845
Citations 28
Authors
Affiliations
Soon will be listed here.
Abstract

The modifications induced by microgravity on the coordinated patterns of movement of the head, trunk, and limbs are reported on extensively. However, apparently there is little data on the masticatory muscles. In normal gravitational conditions, information from the neck and stomatognathic apparatus play a role in maintaining the body's balance and equilibrium. The current pilot study used normal gravity conditions to investigate the hypothesis of a functional coupling between occlusion and neck muscles and body postural oscillations. The immediate effect of modified occlusal surfaces on the contraction pattern of the sternocleidomastoid muscles during maximum voluntary clenching and on the oscillation of the center of foot pressure was analyzed in 11 male astronauts (aged 31-54 yrs). All subjects were healthy and free from pathologies of the neck and stomatognathic apparatus. Occlusal splints were prepared using impressions of their dental arches. The splints were modeled on the mandibular arch, had only posterior contacts, and were modified to obtain a more symmetric, standardized contraction of the masseter and temporalis muscles during teeth clenching. Surface EMG activity of the sternocleidomastoid muscles was recorded during a maximal voluntary clench with and without the splint. Sternocleidomastoid potentials were standardized as percent of the mean potentials recorded during a maximum contralateral rotation of the head, and the symmetry of the EMG waves of left- and right-side muscles was measured. Body sway was assessed with and without the splint, either with eyes open or closed. The variations of the center of foot pressure were analyzed through bivariate analysis, and the area of the 90% standard ellipse was computed. Within each visual condition (eyes open or closed), the difference between the areas of oscillation measured with and without the splint was computed. Muscular activity was more symmetric with the splint. The area of oscillation of the center of foot pressure was larger without the splint than with the splint, both with eyes open and eyes closed. The modifications, induced by the occlusal splint in the sternocleidomastoid muscles' symmetry, and center of foot pressure differential area with closed eyes, were significantly related (p < 0.05): the larger the increment in muscular symmetry, the smaller the area of oscillation with the splint as compared to without the splint. A functionally more symmetric maxillo-mandibular position resulted in a more symmetric sternocleidomastoid muscle contraction pattern and less body sway. Modifications in the contraction of the masticatory muscles may therefore affect the whole body.

Citing Articles

Assessment of the Relationship between Antero-Posterior Dental Malocclusions, Body Posture Abnormalities and Selected Static Foot Parameters in Adults.

Nowak M, Golec J, Golec P, Wieczorek A J Clin Med. 2024; 13(13).

PMID: 38999374 PMC: 11242061. DOI: 10.3390/jcm13133808.


Effect of pain on cranio-cervico-mandibular function and postural stability in people with temporomandibular joint disorders.

Micoogullari M, Yuksel I, Angin S Korean J Pain. 2024; 37(2):164-177.

PMID: 38516795 PMC: 10985482. DOI: 10.3344/kjp.23301.


The Effect of Asymmetrical Occlusion on Surface Electromyographic Activity in Subjects with a Chewing Side Preference: A Preliminary Study.

Zhang Y, Liu K, Shao Z, Lyu C, Zou D Healthcare (Basel). 2023; 11(12).

PMID: 37372836 PMC: 10298563. DOI: 10.3390/healthcare11121718.


Effects of Malocclusion on Maximal Aerobic Capacity and Athletic Performance in Young Sub-Elite Athletes.

El Ouali E, Zouhal H, Bahije L, Ibrahimi A, Benamar B, Kartibou J Sports (Basel). 2023; 11(3).

PMID: 36976957 PMC: 10051721. DOI: 10.3390/sports11030071.


Electromyographic Analysis of Masticatory and Accessory Muscles in Subjects With Implant-Supported Fixed Prostheses: A Three-Arm Comparative Clinical Study.

Raaj V, Raina S, Raina R, Abhishek , Kumari M, Anusha Cureus. 2023; 15(1):e33969.

PMID: 36812127 PMC: 9938720. DOI: 10.7759/cureus.33969.