» Articles » PMID: 16532630

Evaluation of Filler Materials Used for Uniform Load Distribution at Boundaries During Structural Biomechanical Testing of Whole Vertebrae

Overview
Journal J Biomech Eng
Date 2006 Mar 15
PMID 16532630
Citations 11
Authors
Affiliations
Soon will be listed here.
Abstract

This study was designed to compare the compressive mechanical properties of filler materials, Wood's metal, dental stone, and polymethylmethacrylate (PMMA), which are widely used for performing structural testing of whole vertebrae. The effect of strain rate and specimen size on the mechanical properties of the filler materials was examined using standardized specimens and mechanical testing. Because Wood's metal can be reused after remelting, the effect of remelting on the mechanical properties was tested by comparing them before and after remelting. Finite element (FE) models were built to simulate the effect of filler material size and properties on the stiffness of vertebral body construct in compression. Modulus, yield strain, and yield strength were not different between batches (melt-remelt) of Wood's metal. Strain rate had no effect on the modulus of Wood's metal, however, Young's modulus decreased with increasing strain rate in dental stone whereas increased in PMMA. Both Wood's metal and dental stone were significantly stiffer than PMMA (12.7 +/- 1.8 GPa, 10.4 +/- 3.4 GPa, and 2.9 +/- 0.4 GPa, respectively). PMMA had greater yield strength than Wood's metal (62.9 +/- 8.7 MPa and 26.2 +/- 2.6 MPa). All materials exhibited size-dependent modulus values. The FE results indicated that filler materials, if not accounted for, could cause more than 9% variation in vertebral body stiffness. We conclude that Wood's metal is a superior moldable bonding material for biomechanical testing of whole bones, especially whole vertebrae, compared to the other candidate materials.

Citing Articles

Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures.

Zhang R, Zhang W, Yang G, Wang D, Su P, Zhang Y Orthop Surg. 2024; 16(4):953-964.

PMID: 38389204 PMC: 10984827. DOI: 10.1111/os.14004.


Spine biomechanical testing methodologies: The controversy of consensus vs scientific evidence.

Costi J, Ledet E, OConnell G JOR Spine. 2021; 4(1):e1138.

PMID: 33778410 PMC: 7984003. DOI: 10.1002/jsp2.1138.


Vertebral stiffness measured via tomosynthesis-based digital volume correlation is strongly correlated with reference values from micro-CT-based DVC.

Oravec D, Zauel R, Flynn M, Yeni Y Med Eng Phys. 2020; 84:169-173.

PMID: 32977915 PMC: 7522399. DOI: 10.1016/j.medengphy.2020.08.008.


Evaluation of Two Types of Intramedullary Jones Fracture Fixation in a Cyclic and Ultimate Load Model.

Willegger M, Benca E, Hirtler L, Kasparek M, Bauer G, Zandieh S J Orthop Res. 2019; 38(4):911-917.

PMID: 31743452 PMC: 7155054. DOI: 10.1002/jor.24530.


Digital tomosynthesis based digital volume correlation: A clinically viable noninvasive method for direct measurement of intravertebral displacements using images of the human spine under physiological load.

Oravec D, Flynn M, Zauel R, Rao S, Yeni Y Med Phys. 2019; 46(10):4553-4562.