» Articles » PMID: 16527550

High Throughput Therapeutic Drug Monitoring of Clozapine and Metabolites in Serum by On-line Coupling of Solid Phase Extraction with Liquid Chromatography-mass Spectrometry

Overview
Publisher Elsevier
Date 2006 Mar 11
PMID 16527550
Citations 3
Authors
Affiliations
Soon will be listed here.
Abstract

The characteristics of automated on-line solid phase extraction with liquid chromatography-mass spectrometry (SPE-LC-MS) are very amenable for flexibility and throughput in therapeutic drug monitoring (TDM). We demonstrate this concept of automated, on-line SPE-LC-MS for the analysis of clozapine and metabolites (desmethylclozapine and clozapine-N-oxide) in serum. Method development, optimisation and validation are described and a comparison with previously published methods for the determination of clozapine and metabolites in serum and plasma is made. Optimisation of chromatographic and SPE conditions for increased throughput resulted in SPE-LC-MS cycle times of only about 2.2 min, demonstrating the great potential of automated on-line SPE-LC-MS for TDM. The new method is shown to be clearly favourable, in particular in terms of ease of sample handling, throughput and detection limits. Recovery is essentially quantitative. Detection limits are at about 0.15-0.3 ng ml(-1), depending on the ionisation source used. Calibration follows a quadratic model for clozapine and its N-oxide and a linear model for the desmethyl metabolite (all cases: R > 0.99). Accuracy, evaluated at three concentration levels spanning the whole therapeutic range, shows that bias is less than 10%. Precision (intra - and inter assay) ranges from about 5% R.S.D. at the high end of the therapeutic range (700-1,000 ng ml(-1)) to about 20% R.S.D. (OECD defined limit) at the lower limit of quantitation ( approximately 50 ng ml(-1)). The lower limit of quantitation is well below the low end of the therapeutic range at 350 ng ml(-1).

Citing Articles

Development of an ultra fast online-solid phase extraction (SPE) liquid chromatography electrospray tandem mass spectrometry (LC-ESI-MS/MS) based approach for the determination of drugs in pharmacokinetic studies.

Schebb N, Inceoglu B, Rose T, Wagner K, Hammock B Anal Methods. 2011; 3(2):420-428.

PMID: 21660124 PMC: 3110015. DOI: 10.1039/C0AY00714E.


Rapid liquid chromatography/tandem mass spectrometer (LCMS) method for clozapine and its metabolite N-desmethyl clozapine (norclozapine) in human serum.

Rao L, Snyder M, Vallaro G J Clin Lab Anal. 2009; 23(6):394-8.

PMID: 19927349 PMC: 6649014. DOI: 10.1002/jcla.20345.


Current literature in mass spectrometry.

J Mass Spectrom. 2007; 42(1):127-38.

PMID: 17199253 PMC: 7166443. DOI: 10.1002/jms.1070.