» Articles » PMID: 16518965

Clinical Performance of the New RRoche COBAS TaqMan HCV Test and High Pure System for Extraction, Detection and Quantitation of HCV RNA in Plasma and Serum

Overview
Journal Antivir Ther
Publisher Sage Publications
Date 2006 Mar 8
PMID 16518965
Citations 9
Authors
Affiliations
Soon will be listed here.
Abstract

We evaluated the Roche COBAS TaqMan HCV Test For Use With The High Pure System (TaqMan HPS; Roche Diagnostics), for the extraction, detection and quantitation of hepatitis C virus (HCV) RNA in serum or plasma of HCV-infected individuals. The TaqMan HPS is a real-time PCR assay with a reported linear dynamic range of 3.0x10(1) to 2.0x10(8) HCV RNA IU/ml, and a reported lower limit of detection (LLD) of 10 IU/ml. Calculation of the HCV RNA titre is based upon an external standard curve in the presence of an internal control. Intra-assay and inter-assay variation were small in reference panel members with HCV RNA > or =100 IU/ml. Genotype performance and quantitative correlation between the TaqMan HPS and the bDNA (VERSANT HCV 3.0 assay; Bayer Diagnostics), assessed in 59 patient samples, were good for HCV genotype 1 but poor for genotypes 2, 3 and 4. For genotypes 2, 3 and 4, values obtained from the TaqMan HPS were in general 0.5 log lower than those from the bDNA. Sensitivity was poor in low viral titre samples of genotypes 1, 2, 3 and 4. The LLD (95%) was estimated at 41 HCV RNA IU/ml for genotype 4. The TaqMan HPS underestimates HCV RNA at all levels in plasma and serum from HCV-infected individuals, and the LLD should be reconsidered. This is clinically relevant because underestimation of HCV RNA levels during therapy may lead physicians into making incorrect treatment decisions.

Citing Articles

Diagnostic Accuracy of the HemoCue Hb 301, STAT-Site MHgb and URIT-12 Point-of-Care Hemoglobin Meters in a Central Laboratory and a Community Based Clinic in Durban, South Africa.

Jaggernath M, Naicker R, Madurai S, Brockman M, Ndungu T, Gelderblom H PLoS One. 2016; 11(4):e0152184.

PMID: 27046200 PMC: 4821624. DOI: 10.1371/journal.pone.0152184.


A multiplex two-color real-time PCR method for quality-controlled molecular diagnostic testing of FFPE samples.

Yeo J, Crawford E, Blomquist T, Stanoszek L, Dannemiller R, Zyrek J PLoS One. 2014; 9(2):e89395.

PMID: 24586747 PMC: 3931751. DOI: 10.1371/journal.pone.0089395.


Accurate detection and quantification of the fish viral hemorrhagic Septicemia virus (VHSv) with a two-color fluorometric real-time PCR assay.

Pierce L, Willey J, Palsule V, Yeo J, Shepherd B, Crawford E PLoS One. 2013; 8(8):e71851.

PMID: 23977162 PMC: 3748128. DOI: 10.1371/journal.pone.0071851.


Performance of the novel Qiagen artus QS-RGQ viral load assays compared to that of the Abbott RealTime system with genetically diversified HIV and hepatitis C Virus plasma specimens.

Drexler J, Reber U, Wuttkopf A, Eis-Hubinger A, Drosten C J Clin Microbiol. 2012; 50(6):2114-7.

PMID: 22403428 PMC: 3372116. DOI: 10.1128/JCM.05874-11.


A novel diagnostic target in the hepatitis C virus genome.

Drexler J, Kupfer B, Petersen N, Grotto R, Rodrigues S, Grywna K PLoS Med. 2009; 6(2):e31.

PMID: 19209955 PMC: 2637920. DOI: 10.1371/journal.pmed.1000031.