Objective: Whole-body plethysmography is a common method of measuring pulmonary function. Although this technique provides a sensitive measure of pulmonary function, it can be problematic and unsuitable in some patients. The development of more accessible techniques would be beneficial.

Methods: A prospective study was performed to validate diaphragm ultrasonography as an alternative to whole-body plethysmography in patients referred for pulmonary function testing. Diaphragm movement and position were assessed by ultrasonography after standard pulmonary function testing using whole-body plethysmography.

Results: A wide range of lung function was observed. Standard lung volumes were as follows: total lung capacity, 5.57 +/- 1.31 L, residual volume, 2.27 +/- 0.56 L; and vital capacity, 3.30 +/- 0.98 L (mean +/- SD). The ratio of forced expiratory volume in 1 second to forced vital capacity was calculated as 0.69 +/- 0.08. Ultrasonography showed that mean diaphragm excursion values were 11.1 +/- 3.8 mm (2-dimensional), 14.7 +/- 4.1 mm during quiet breathing (M-mode), and 14.8 +/- 3.9 mm during a maximal sniff (M-mode). The velocity of diaphragm movement rose sharply during the sniff maneuver from 15.2 +/- 5.8 mm/s during quiet breathing to 104.0 +/- 33.4 mm/s. Static 2-dimensional measures of diaphragm position at the end of quiet inspiration or expiration correlated with standard measures of lung volume on plethysmography (eg, a correlation coefficient of 0.83 was obtained with end inspiration and vital capacity). All measures of diaphragm movement (whether by 2-dimensional or M-mode techniques) were poorly correlated with any lung volumes measured.

Conclusions: These data suggest that dynamic measurements using diaphragm ultrasonography provide a relatively poor measure of pulmonary function in relation to whole-body plethysmography.

Citing Articles

Ultrasonographic evaluation of diaphragm fatigue in healthy humans.

Illidi C, Romer L Exp Physiol. 2025; 110(3):478-493.

PMID: 39780750 PMC: 11868021. DOI: 10.1113/EP092322.


Ultrasound evaluation of diaphragmatic function in patients with idiopathic pulmonary fibrosis: a retrospective observational study.

Milesi J, Boussuges A, Habert P, Bermudez J, Reynaud-Gaubert M, Delliaux S Respir Res. 2023; 24(1):259.

PMID: 37898765 PMC: 10613389. DOI: 10.1186/s12931-023-02577-1.


Diaphragmatic ultrasound can help evaluate pulmonary dysfunction in patients with stroke.

Chen Y, Zhou S, Liao L, He J, Tang D, Wu W Front Neurol. 2023; 14:1061003.

PMID: 37144002 PMC: 10151578. DOI: 10.3389/fneur.2023.1061003.


Ultrasonographic Assessment of Diaphragmatic Function and Its Clinical Application in the Management of Patients with Acute Respiratory Failure.

Saad M, Pini S, Danzo F, Mandurino Mirizzi F, Arena C, Tursi F Diagnostics (Basel). 2023; 13(3).

PMID: 36766515 PMC: 9914801. DOI: 10.3390/diagnostics13030411.


Ultrasonographic evaluation of incidence of diaphragmatic paralysis following different volumes of supraclavicular brachial plexus block- A prospective randomized double blinded study.

Johnson J, Daniel S Saudi J Anaesth. 2022; 16(1):58-64.

PMID: 35261590 PMC: 8846228. DOI: 10.4103/sja.sja_568_21.