» Articles » PMID: 16402262

The Role of Biofilm Infection in Urology

Overview
Journal World J Urol
Specialty Urology
Date 2006 Jan 13
PMID 16402262
Citations 38
Authors
Affiliations
Soon will be listed here.
Abstract

In the process of endourological development a great variety of foreign bodies have been invented besides urinary catheters on which biofilm can be formed. Bacteria in the biofilm are less sensible to antibiotics. An additional problem of medical biomaterials in the urinary tract environment is the development of encrustation and consecutive obstruction. In this review, we tried to sum up the conditions where biofilm formation has a great impact on the development or maintenance of urological infections and on treatment success. Modification of the biomaterial surface seems to be the most promising prevention strategy for bacterial biofilms. Easier methods for diagnosing and quantifying biofilm infection, to develop more specific antimicrobial agents and ideal device surfaces would surely help the fight against biofilm formation.

Citing Articles

The Role of Butirprost as an Adjuvant in Enhancing the Effect of Antibiotics in Patients Affected by Chronic Bacterial Prostatitis: A Randomized Prospective Trial.

Crocetto F, Calogero A, Santangelo M, Fernicola A, Varlese F, Mirto B Medicina (Kaunas). 2025; 61(1).

PMID: 39859130 PMC: 11767095. DOI: 10.3390/medicina61010148.


Research on a new type of ureteral stent material Zn-2Cu-0.5Fe-xMn with controllable degradation rate.

Zheng J, Zheng Y, Sun P, Zhu D, Fan W, Huang T Heliyon. 2024; 10(17):e37629.

PMID: 39290270 PMC: 11407047. DOI: 10.1016/j.heliyon.2024.e37629.


New insights into the prevention of ureteral stents encrustation.

Guo H, Yuan J Open Med (Wars). 2023; 18(1):20230854.

PMID: 38075034 PMC: 10710215. DOI: 10.1515/med-2023-0854.


AC Electromagnetic Field Controls the Biofilms on the Glass Surface by & Inhibition Effect.

Aoyama N, Kanematsu H, Barry D, Miura H, Ogawa A, Kogo T Materials (Basel). 2023; 16(21).

PMID: 37959648 PMC: 10649311. DOI: 10.3390/ma16217051.


Safe duration of silicon catheter replacement in urological patients.

Oyortey M, Essoun S, Ali M, Abdul-Rahman M, Welbeck J, Dakubo J Ghana Med J. 2023; 57(1):66-74.

PMID: 37576373 PMC: 10416272. DOI: 10.4314/gmj.v57i1.10.


References
1.
Nickel J . Catheter-associated urinary tract infection: new perspectives on old problems. Can J Infect Control. 1991; 6(2):38-42. View

2.
Shigeta M, Komatsuzawa H, Sugai M, Suginaka H, Usui T . Effect of the growth rate of Pseudomonas aeruginosa biofilms on the susceptibility to antimicrobial agents. Chemotherapy. 1997; 43(2):137-41. DOI: 10.1159/000239548. View

3.
Choong S, Wood S, Fry C, Whitfield H . Catheter associated urinary tract infection and encrustation. Int J Antimicrob Agents. 2001; 17(4):305-10. DOI: 10.1016/s0924-8579(00)00348-4. View

4.
Carson C . Infections in genitourinary prostheses. Urol Clin North Am. 1989; 16(1):139-47. View

5.
Habash M, Reid G . Microbial biofilms: their development and significance for medical device-related infections. J Clin Pharmacol. 1999; 39(9):887-98. DOI: 10.1177/00912709922008506. View