» Articles » PMID: 16307568

Early Loading of Non-submerged Titanium Implants with a Sandblasted and Acid-etched Surface. 5-year Results of a Prospective Study in Partially Edentulous Patients

Overview
Specialty Dentistry
Date 2005 Nov 26
PMID 16307568
Citations 30
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The aim of this prospective cohort study was to evaluate the success rate of titanium screw-type implants with the sandblasted and acid-etched (SLA) surface loaded early, after 6 weeks of healing.

Material And Methods: A total of 104 implants were inserted into posterior sites of 51 partially edentulous patients exhibiting bone densities of class I-III. After a healing period of 6 weeks, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 3, 12, 24, 36, 48 and 60 months for clinical and radiographic examination.

Results: One implant failed to integrate during healing, and three implants were lost to follow-up and were considered drop-outs. The remaining 100 implants showed favorable clinical and radiographic findings at the 5-year examination. The peri-implant soft tissues were stable over time; the mean probing depths and mean attachment levels did not change during the follow-up period. None of the radiographs exhibited signs of continuous peri-implant radiolucency, which confirmed ankylotic stability for all 100 implants. The measurement of the bone crest levels (DIB values) indicated stability as well. Based on strict success criteria, all 100 implants were considered successfully integrated, resulting in a 5-year success rate of 99%.

Conclusion: This prospective study using an early loading protocol with 6 weeks of healing demonstrated that titanium implants with the SLA surface can achieve and maintain successful tissue integration with high predictability for at least 5 years of follow-up in selected patients and sites.

Citing Articles

Osseodensification technique in crestal maxillary sinus elevation-A narrative review.

Gaspar J, Mazor Z, Bonfante E Clin Implant Dent Relat Res. 2024; 27(1):e13399.

PMID: 39350694 PMC: 11739684. DOI: 10.1111/cid.13399.


Does crown-to-implant ratio affect marginal bone loss around a single short implant at the posterior of the mandible?.

Tabrizi R, Mehrabi P, Shafiei S, Azimi A, Moslemi H Natl J Maxillofac Surg. 2024; 15(2):273-277.

PMID: 39234123 PMC: 11371288. DOI: 10.4103/njms.njms_27_23.


Infrared diode laser enhances human periodontal ligament stem cells behaviour on titanium dental implants.

El-Dahab M, El Deen G, Aly R, Gheith M Sci Rep. 2024; 14(1):4155.

PMID: 38378776 PMC: 10879096. DOI: 10.1038/s41598-024-54585-w.


Three-Dimensional Peri-Implant Tissue Changes in Immediately vs. Early Placed Tapered Implants Restored with Two Different Ceramic Materials-1 Year Results.

Strasding M, Jeong Y, Marchand L, Hicklin S, Sailer I, Sun M Materials (Basel). 2023; 16(16).

PMID: 37629928 PMC: 10456968. DOI: 10.3390/ma16165636.


Incidence of Peri-Implantitis, Technical and Biological Complications of Single Implants Placed with Flap or Flapless Surgery-A 10-12-Year Case-Series.

Naeini E, Atashkadeh M, Jacquet W, DHaese J, De Bruyn H J Clin Med. 2023; 12(11).

PMID: 37297870 PMC: 10253636. DOI: 10.3390/jcm12113668.