» Articles » PMID: 16270290

STIR Vs. T1-weighted Fat-suppressed Gadolinium-enhanced MRI of Bone Marrow Edema of the Knee: Computer-assisted Quantitative Comparison and Influence of Injected Contrast Media Volume and Acquisition Parameters

Overview
Date 2005 Nov 5
PMID 16270290
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare short tau inversion recovery (STIR) and T1-weighted (T1w) gadolinium (Gd)-enhanced fat-suppressed MRI of bone marrow edema (BME) of the knee, and investigate the influence of injected contrast media volume and variation of major acquisition parameters on apparent BME volume and signal contrast.

Materials And Methods: STIR and T1w Gd-enhanced fat-suppressed images were obtained from 30 patients with BME of the knee. Two groups of patients were examined with different MR scanners, acquisition parameters, and contrast media volumes. For both sequences, BME volume and signal contrast were assessed by computer-assisted quantification, and were compared through their arithmetic means and correlation coefficients (r(2)). The injected contrast media volume was also correlated with BME volume and signal contrast differences between sequences.

Results: A strong correlation between the STIR and Gd-enhanced T1w images was found for BME volume (r(2) = 0.96-0.99) and BME signal contrast (r(2) = 0.86-0.94). Despite the differences in MR acquisition parameters and injected contrast media volume, both sequences depicted an almost identical BME volume in both groups. Contrast media volume showed a moderate correlation (r(2) = 0.40) with BME volume differences.

Conclusion: STIR is the optimum method for determining the size and signal contrast of BME. The injected contrast media volume appears to have only a limited influence on apparent BME volume.

Citing Articles

Axial Skeleton Bone Marrow Changes in Inflammatory Rheumatologic Disorders.

Reijnierse M Semin Musculoskelet Radiol. 2023; 27(1):91-102.

PMID: 36868247 PMC: 9984269. DOI: 10.1055/s-0043-1761496.


Towards a simplified fluid-sensitive MRI protocol in small joints of the hand in early arthritis patients: reliability between modified Dixon and regular Gadolinium enhanced TSE fat saturated MRI-sequences.

Boeren A, Niemantsverdriet E, Verstappen M, Wouters F, Bloem J, Reijnierse M Skeletal Radiol. 2022; 52(6):1193-1202.

PMID: 36441238 PMC: 7615876. DOI: 10.1007/s00256-022-04238-8.


Evaluating the Impact of High Intensity Interval Training on Axial Psoriatic Arthritis Based on MR Images.

Chronaiou I, Giskeodegard G, Neubert A, Hoffmann-Skjostad T, Thomsen R, Hoff M Diagnostics (Basel). 2022; 12(6).

PMID: 35741229 PMC: 9222014. DOI: 10.3390/diagnostics12061420.


Percussion test: description and diagnostic accuracy of a new manual test for bone marrow edema of the knee.

Sansone V, Galluzzo A, Maiorano E, Polatti M, Pascale V BMC Musculoskelet Disord. 2022; 23(1):68.

PMID: 35042479 PMC: 8767745. DOI: 10.1186/s12891-022-05028-y.


Treating Full Depth Cartilage Defects with Intraosseous Infiltration of Plasma Rich in Growth Factors: An Experimental Study in Rabbits.

Torres-Torrillas M, Damia E, Ceron J, Carrillo J, Pelaez P, Miguel L Cartilage. 2021; 13(2_suppl):766S-773S.

PMID: 34861782 PMC: 8804721. DOI: 10.1177/19476035211057246.