The Impact of Respiration on Left Atrial and Pulmonary Venous Anatomy: Implications for Image-guided Intervention

Overview
Journal Heart Rhythm
Publisher Elsevier
Date 2005 Oct 29
PMID 16253905
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Image-guided intervention using pre-acquired CT/MR 3-dimensional images is an emerging strategy for atrial fibrillation (AF) ablation but may be limited by its use of static images to depict dynamic physiology. The effect of biologic factors such as respiration on the left atrial-pulmonary venous (LA-PV) anatomy is not well understood but is likely to have important implications. Conventional CT/MR imaging is performed during an inspiratory breath-hold, while electroanatomical mapping (EAM) during "quiet" breathing approximates an expiratory breath-hold. This study examined the effects of respiration on LA-PV anatomy and the error introduced by respiration on the integration of EAM with 3D MR imaging.

Methods: Pre-procedural MRI angiography was performed at both end-expiration (EXP) and end-inspiration (INSP) in 20 patients undergoing AF catheter ablation. 3D INSP and EXP surface reconstructions of the LA-PVs were compared. In selected pts, EAM data acquired during the ablation procedure (n=7) were integrated with the 3D MRI datasets.

Results: Qualitative assessment of the INSP and EXP 3D images revealed splaying of the PVs and reduction in PV caliber of the right-sided PVs during held inspiration. After aligning these two datasets, the average surface-to-surface distance calculated by region ranged from 1.99mm (right middle PV) to 3.79mm (left superior PV). Registration of the EAM to the MRI models was better for the EXP dataset (2.30+/-0.73mm) than the INSP dataset (3.03+/-0.57mm; p=0.004).

Conclusion: There are significant changes in LA-PV anatomy with respiration. MR images acquired during standard held inspiration may introduce unnecessary errors in registration during image-guided intervention.

Citing Articles

Does merged three-dimensional mapping improve contact force and long-term procedure outcome in atrial fibrillation ablation? (MICRO-AF study): a prospective randomized controlled study.

Shin D, Roh S, Ahn J, Park S, Kim D, Han S Int J Cardiovasc Imaging. 2021; 37(12):3431-3438.

PMID: 34255269 DOI: 10.1007/s10554-021-02335-8.


A Prospective Assessment of Optimal Mechanical Ventilation Parameters for Pediatric Catheter Ablation.

Janson C, Ceresnak S, Choi J, Dubin A, Motonaga K, Mann G Pediatr Cardiol. 2018; 40(1):126-132.

PMID: 30178187 DOI: 10.1007/s00246-018-1968-7.


The seamless integration of three-dimensional rotational angiography images into electroanatomical mapping systems to guide catheter ablation of atrial fibrillation.

Fujita S, Fujii E, Kagawa Y, Inoue K, Yamada T, Ito M Heart Vessels. 2018; 33(11):1373-1380.

PMID: 29736557 DOI: 10.1007/s00380-018-1180-y.


Cardiac Image Registration: Rotational Error Correction and Gated Stabilization for Cardiac Motion.

Sra J, Soubelet E, Vaillant R, Krum D, Hare J, Belanger B J Atr Fibrillation. 2017; 3(5):250.

PMID: 28496684 PMC: 4956075. DOI: 10.4022/jafib.250.


Left Atrial Image Registration to Guide Catheter Ablation of Atrial Fibrillation: In the Eye of the Technology.

Centurion O J Atr Fibrillation. 2017; 1(3):133.

PMID: 28496593 PMC: 4956378. DOI: 10.4022/jafib.133.