» Articles » PMID: 16230232

Consistency of Implantation of a Total Knee Arthroplasty with a Non-image-based Navigation System: a Case-control Study of 235 Cases Compared with 235 Conventionally Implanted Prostheses

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2005 Oct 19
PMID 16230232
Citations 76
Authors
Affiliations
Soon will be listed here.
Abstract

The aim of the study was to assess the consistency of the non-image-based navigation system OrthoPilot, Aesculap, Tuttlingen, Germany, in total knee arthroplasty (TKA) implantation in 5 European centers. Two hundred thirty-five TKAs implanted with this navigation system were matched (according to severity of the preoperative coronal deformation and body mass index) to a historical control group of 235 TKAs implanted with a conventional technique. Consistency of implantation was studied on a 3-month postoperative radiological control with coronal long-leg and sagittal standard x-rays. The use of the OrthoPilot navigation system allowed a statistically significant improvement in the consistent placement of both tibial and femoral components. In accordance with current literature, survival of the navigated implanted prostheses is expected to be longer.

Citing Articles

Utilizing Evolved Extramedullary Techniques for Conventional Knee Arthroplasty in Post-traumatic Knee Arthritis With Retained Hardware: A Retrospective Analysis.

Chang C, Tseng Y, Chen Y, Yang C Cureus. 2025; 17(2):e79402.

PMID: 39995591 PMC: 11847752. DOI: 10.7759/cureus.79402.


Early Radiographic and Clinical Outcomes of Robotic-arm-assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial.

Geng X, Zheng Y, Li Y, Zhao M, Liu Y, Li Z Orthop Surg. 2024; 16(11):2732-2740.

PMID: 39135273 PMC: 11541113. DOI: 10.1111/os.14196.


Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty.

Cosendey K, Stanovici J, Cadas H, Omoumi P, Jolles B, Favre J J Clin Med. 2024; 13(5).

PMID: 38592116 PMC: 10931633. DOI: 10.3390/jcm13051293.


Robotic-assisted mechanically aligned total knee arthroplasty does not lead to better clinical and radiological outcomes when compared to conventional TKA: a systematic review and meta-analysis of randomized controlled trials.

Bensa A, Sangiorgio A, Deabate L, Illuminati A, Pompa B, Filardo G Knee Surg Sports Traumatol Arthrosc. 2023; 31(11):4680-4691.

PMID: 37270464 DOI: 10.1007/s00167-023-07458-0.


The coronal plane alignment of the knee classification does not correlate with the functional knee phenotype classification.

Jenny J, Baldairon F Knee Surg Sports Traumatol Arthrosc. 2023; 31(9):3906-3911.

PMID: 36947230 DOI: 10.1007/s00167-023-07394-z.