» Articles » PMID: 16214014

Computer Assisted Navigation in Total Knee Arthroplasty: Comparison with Conventional Methods

Overview
Journal J Arthroplasty
Specialty Orthopedics
Date 2005 Oct 11
PMID 16214014
Citations 67
Authors
Affiliations
Soon will be listed here.
Abstract

The success of knee arthroplasty is dependent on many factors. Postoperative extremity and component alignment are important determinants of outcome and longevity. Malalignment (>3 degrees ) results in higher failure rates. Computer-assisted navigation devices were developed to improve implant positioning. This study evaluated the early outcomes of a high-volume fellowship-trained surgeon relative to component positioning and limb alignment using an image-free navigation system. The navigation group consisted of 116 consecutive patients, and the conventional group consisted of 51 consecutive patients. The postoperative mechanical axis was within 3 degrees of neutral mechanical alignment in 95% of the navigation cases vs 84% of the conventional cases (P < .02). The range of the alignment and component position measurements narrowed, and the undesired outliers decreased. Accuracy was improved with navigation. Navigation was a viable device to improve the outcome of total knee arthroplasty relative to limb and component alignment.

Citing Articles

The influence of implant factors on patient outcomes in primary total knee arthroplasty.

Van Meirhaeghe J, Harris I, Cuthbert A, Lorimer M, McAuliffe M, Adie S J Orthop. 2024; 58:154-160.

PMID: 39157416 PMC: 11326491. DOI: 10.1016/j.jor.2024.07.011.


Early Radiographic and Clinical Outcomes of Robotic-arm-assisted versus Conventional Total Knee Arthroplasty: A Multicenter Randomized Controlled Trial.

Geng X, Zheng Y, Li Y, Zhao M, Liu Y, Li Z Orthop Surg. 2024; 16(11):2732-2740.

PMID: 39135273 PMC: 11541113. DOI: 10.1111/os.14196.


Computerized surgical navigation resection of pelvic region simulated bone tumors using skin fiducial marker registration: an in vitro cadaveric study.

Whitaker J, Are T, Edwards C, Nyland J, Sachdeva S, Carlson J Eur J Orthop Surg Traumatol. 2024; 34(5):2645-2652.

PMID: 38743103 DOI: 10.1007/s00590-024-03978-8.


Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty.

Cosendey K, Stanovici J, Cadas H, Omoumi P, Jolles B, Favre J J Clin Med. 2024; 13(5).

PMID: 38592116 PMC: 10931633. DOI: 10.3390/jcm13051293.


Radiological Evaluation of OrthAlign-A Novel Handheld Navigation System used in Total Knee Replacement.

Patel J, Yadav K, Daga R, Sadaria M J Pharm Bioallied Sci. 2023; 15(Suppl 2):S1160-S1163.

PMID: 37694038 PMC: 10485549. DOI: 10.4103/jpbs.jpbs_181_23.