» Articles » PMID: 16204879

Statistical Dynamic Image Reconstruction in State-of-the-art High-resolution PET

Overview
Journal Phys Med Biol
Publisher IOP Publishing
Date 2005 Oct 6
PMID 16204879
Citations 58
Authors
Affiliations
Soon will be listed here.
Abstract

Modern high-resolution PET is now more than ever in need of scrutiny into the nature and limitations of the imaging modality itself as well as image reconstruction techniques. In this work, we have reviewed, analysed and addressed the following three considerations within the particular context of state-of-the-art dynamic PET imaging: (i) the typical average numbers of events per line-of-response (LOR) are now (much) less than unity, (ii) due to the physical and biological decay of the activity distribution, one requires robust and efficient reconstruction algorithms applicable to a wide range of statistics and (iii) the computational considerations in dynamic imaging are much enhanced (i.e., more frames to be stored and reconstructed). Within the framework of statistical image reconstruction, we have argued theoretically and shown experimentally that the sinogram non-negativity constraint (when using the delayed-coincidence and/or scatter-subtraction techniques) is especially expected to result in an overestimation bias. Subsequently, two schemes are considered: (a) subtraction techniques in which an image non-negativity constraint has been imposed and (b) implementation of random and scatter estimates inside the reconstruction algorithms, thus enabling direct processing of Poisson-distributed prompts. Both techniques are able to remove the aforementioned bias, while the latter, being better conditioned theoretically, is able to exhibit superior noise characteristics. We have also elaborated upon and verified the applicability of the accelerated list-mode image reconstruction method as a powerful solution for accurate, robust and efficient dynamic reconstructions of high-resolution data (as well as a number of additional benefits in the context of state-of-the-art PET).

Citing Articles

Imaging the translocator protein 18 kDa within cognitive control and declarative memory circuits in virally suppressed people with HIV.

Rubin L, Maki P, Du Y, Sweeney S, OToole R, Nam H AIDS. 2024; 39(2):133-142.

PMID: 39405127 PMC: 11717590. DOI: 10.1097/QAD.0000000000004034.


PARALLELPROJ-an open-source framework for fast calculation of projections in tomography.

Schramm G, Thielemans K Front Nucl Med. 2024; 3:1324562.

PMID: 39355030 PMC: 11440996. DOI: 10.3389/fnume.2023.1324562.


A radioligand for in vitro autoradiography of CSF1R in post-mortem CNS tissues.

Foss C, Naik R, Das D, Cha H, Minn I, Hall A EJNMMI Res. 2024; 14(1):76.

PMID: 39186197 PMC: 11347546. DOI: 10.1186/s13550-024-01133-2.


How to obtain the image-derived blood concentration from Zr-immuno-PET scans.

Wijngaarden J, Ahbari A, Pouw J, Greuter H, Bahce I, Zwezerijnen G EJNMMI Phys. 2024; 11(1):16.

PMID: 38321232 PMC: 10847076. DOI: 10.1186/s40658-024-00621-7.


[F]FNDP PET neuroimaging test-retest repeatability and whole-body dosimetry in humans.

Du Y, Coughlin J, Amindarolzarbi A, Sweeney S, Harrington C, Brosnan M Eur J Nucl Med Mol Imaging. 2023; 50(12):3659-3665.

PMID: 37458759 DOI: 10.1007/s00259-023-06331-z.