» Articles » PMID: 16133620

Reducing Radiation Dose in Emergency Computed Tomography with Automatic Exposure Control Techniques

Overview
Journal Emerg Radiol
Date 2005 Sep 1
PMID 16133620
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Computed tomography (CT) scanning is being increasingly used for evaluation of trauma, which most commonly involves younger individuals. As younger patients are at higher risk for radiation-induced cancer compared to older patients, radiation dose reduction is an important issue in emergency CT scanning. With automatic exposure control techniques, users select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. These techniques can help in reducing radiation dose by 10-60% in most instances. This review article presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of automatic exposure control in emergency CT scanning.

Citing Articles

Crohn's Disease: Radiological Answers to Clinical Questions and Review of the Literature.

Minordi L, DAngelo F, Privitera G, Papa A, Larosa L, Laterza L J Clin Med. 2024; 13(14).

PMID: 39064186 PMC: 11277847. DOI: 10.3390/jcm13144145.


Management of high-grade renal traumas with collecting system injuries.

Locke J, Neu S, Navaratnam R, Phillips A, Nathens A, Herschorn S Can Urol Assoc J. 2021; 15(11):E588-E592.

PMID: 33999807 PMC: 8641907. DOI: 10.5489/cuaj.7115.


Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis.

Mehnati P, Malekzadeh R, Sooteh M Radiol Phys Technol. 2019; 12(1):6-25.

PMID: 30790174 DOI: 10.1007/s12194-019-00500-2.


Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE).

Bashier E, Suliman I Radiol Med. 2018; 123(6):424-431.

PMID: 29380262 DOI: 10.1007/s11547-018-0859-6.


Evaluation of AAPM Reports 204 and 220: Estimation of effective diameter, water-equivalent diameter, and ellipticity ratios for chest, abdomen, pelvis, and head CT scans.

Burton C, Szczykutowicz T J Appl Clin Med Phys. 2017; 19(1):228-238.

PMID: 29178549 PMC: 5768014. DOI: 10.1002/acm2.12223.


References
1.
Parsons P . Energy, stress and the invalid linear no-threshold premise: a generalization illustrated by ionizing radiation. Biogerontology. 2003; 4(4):227-31. DOI: 10.1023/a:1025195002489. View

2.
Ptak T, Rhea J, Novelline R . Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience. Radiology. 2003; 229(3):902-5. DOI: 10.1148/radiol.2293021651. View

3.
Kalra M, Maher M, Toth T, Schmidt B, Westerman B, Morgan H . Techniques and applications of automatic tube current modulation for CT. Radiology. 2004; 233(3):649-57. DOI: 10.1148/radiol.2333031150. View

4.
Frush D . Pediatric CT: practical approach to diminish the radiation dose. Pediatr Radiol. 2002; 32(10):714-7; discussion 751-4. DOI: 10.1007/s00247-002-0797-1. View

5.
Brenner D, Doll R, Goodhead D, Hall E, Land C, Little J . Cancer risks attributable to low doses of ionizing radiation: assessing what we really know. Proc Natl Acad Sci U S A. 2003; 100(24):13761-6. PMC: 283495. DOI: 10.1073/pnas.2235592100. View