Abstract

Embolization of foreign objects to the pulmonary circulation is an uncommon occurrence. Traditionally, plain radiographs have been used to detect larger, radiodense objects, with axial CT used to localize smaller, less radiodense objects. More recently, the use of multidetector CT has permitted the detection and accurate localization of smaller, relatively radiolucent objects. This case demonstrates the utility of multidetector 3D CT to localize a small, subtle peripheral venous catheter, which can be easily missed on axial CT.

Citing Articles

Pulmonary Embolization of Radiolucent Intravenous Cannula: Endovascular Retrieval.

Giragani S, Singh M, Gonuguntla H, Muthyala S, Alwala S Indian J Radiol Imaging. 2022; 31(4):1036-1038.

PMID: 35136524 PMC: 8817808. DOI: 10.1055/s-0041-1735926.


Radiology of foreign bodies: how do we image them?.

Ingraham C, Mannelli L, Robinson J, Linnau K Emerg Radiol. 2015; 22(4):425-30.

PMID: 25648360 DOI: 10.1007/s10140-015-1294-9.


Computed tomography studies of lung ventilation and perfusion.

Hoffman E, Chon D Proc Am Thorac Soc. 2005; 2(6):492-8, 506.

PMID: 16352755 PMC: 2713338. DOI: 10.1513/pats.200509-099DS.

References
1.
Moore C, Horton K, Fishman E . 3D CT angiography of the kidney. Crit Rev Comput Tomogr. 2003; 44(5):279-304. DOI: 10.3109/bctg.44.5.279.304. View

2.
Johnson P, Heath D, Hofmann L, Horton K, Fishman E . Multidetector-row computed tomography with three-dimensional volume rendering of pancreatic cancer: a complete preoperative staging tool using computed tomography angiography and volume-rendered cholangiopancreatography. J Comput Assist Tomogr. 2003; 27(3):347-53. DOI: 10.1097/00004728-200305000-00008. View

3.
Fishman E, Kuszyk B . 3D imaging: musculoskeletal applications. Crit Rev Diagn Imaging. 2001; 42(1):59-100. View

4.
Horton K, Fishman E . Volume-rendered 3D CT of the mesenteric vasculature: normal anatomy, anatomic variants, and pathologic conditions. Radiographics. 2002; 22(1):161-72. DOI: 10.1148/radiographics.22.1.g02ja30161. View

5.
Horton K, Fishman E . Multidetector-row computed tomography and 3-dimensional computed tomography imaging of small bowel neoplasms: current concept in diagnosis. J Comput Assist Tomogr. 2004; 28(1):106-16. DOI: 10.1097/00004728-200401000-00019. View