Quantitative Analysis of Magnetic Resonance Imaging Susceptibility Artifacts Caused by Neurosurgical Biomaterials: Comparison of 0.5, 1.5, and 3.0 Tesla Magnetic Fields

Overview
Specialties Neurology
Neurosurgery
Date 2005 Aug 30
PMID 16127256
Citations 14
Authors
Affiliations
Soon will be listed here.
Abstract

Magnetic resonance (MR) imaging is an important diagnostic tool for neurosurgical diseases but susceptibility artifacts caused by biomaterial instrumentation frequently causes difficulty in visualizing postoperative changes. The susceptibility artifacts caused by neurosurgical biomaterials were compared quantitatively by 0.5, 1.5, and 3.0 Tesla MR imaging. MR imaging of uniform size and shape of pieces ceramic (zirconia), pure titanium, titanium alloy, and cobalt-based alloy was performed at 0.5, 1.5, and 3.0 Tesla. A linear region of interest was defined across the center of the biomaterial in the transverse direction, and the susceptibility artifact diameter was calculated. Susceptibility artifacts developed around all biomaterials at all magnetic field strengths. The artifact diameters caused by pure titanium, titanium alloy, and cobalt-based alloy increased in the order of 0.5, 1.5, to 3.0 Tesla magnetic fields. The artifact diameter of ceramic was not influenced by magnetic field strength, and was the smallest of all biomaterials at all magnetic field strengths. The artifacts caused by biomaterials except ceramic increase with the magnetic field strength. Ceramic instrumentation will minimize artifacts in all magnetic fields.

Citing Articles

Improved metal suppression using new generation low-field MRI: a biophantom feasibility study.

Luitjens J, Ziegeler K, Yoon D, Gassert F, Bhattacharjee R, Manatrakul R Skeletal Radiol. 2024; .

PMID: 39365346 DOI: 10.1007/s00256-024-04809-x.


MRI susceptibility artefacts caused by orthodontic wire.

Iwamoto Y, Shimamoto H, Felemban D, Terai T, Kreiborg S, Mallya S Dentomaxillofac Radiol. 2024; 53(6):396-406.

PMID: 38870528 PMC: 11358636. DOI: 10.1093/dmfr/twae023.


Numerical approach to investigate MR imaging artifacts from orthopedic implants at different field strengths according to ASTM F2119.

Spronk T, Kraff O, Schaefers G, Quick H MAGMA. 2023; 36(5):725-735.

PMID: 36933090 PMC: 10504103. DOI: 10.1007/s10334-023-01074-2.


Visual and quantitative assessment of hip implant-related metal artifacts at low field MRI: a phantom study comparing a 0.55-T system with 1.5-T and 3-T systems.

Breit H, Vosshenrich J, Clauss M, Weikert T, Stieltjes B, Kovacs B Eur Radiol Exp. 2023; 7(1):5.

PMID: 36750494 PMC: 9905379. DOI: 10.1186/s41747-023-00320-5.


Reliability of slice-encoding for metal artefact correction (SEMAC) MRI to identify prosthesis loosening in patients with painful total hip arthroplasty - a single centre, prospective, surgical validation study.

Takahashi T, Thaker S, Lettieri G, Redmond A, Backhouse M, Stone M Br J Radiol. 2022; 95(1132):20210940.

PMID: 35148205 PMC: 9153704. DOI: 10.1259/bjr.20210940.