» Articles » PMID: 16076556

Reader Variability in Reporting Breast Imaging According to BI-RADS Assessment Categories (the Florence Experience)

Overview
Journal Breast
Publisher Elsevier
Specialties Endocrinology
Oncology
Date 2005 Aug 4
PMID 16076556
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

The inter- and intraobserver agreement (K statistic) in reporting according to BI-RADS assessment categories was tested on 12 dedicated breast radiologists, with little prior working knowledge of BI-RADS, reading a set of 50 lesions (29 malignant, 21 benign). Intraobserver agreement (four categories: R2, R3, R4, R5) was fair (0.21-0.40), moderate (0.41-0.60), substantial (0.61-0.80) or almost perfect (>0.80) for one, two, five or four radiologists, or (six categories: R2, R3, R4a, R4b, R4c, R5) fair, moderate, substantial or almost perfect for three, three, three or three radiologists, respectively. Interobserver agreement (four categories) was fair, moderate or substantial for three, six, or three radiologists, or (six categories) slight, fair or moderate for one, six, or five radiologists. Major disagreement occurred for intermediate categories (R3=0.12, R4=0.25, R4a=0.08, R4b=0.07, R4c=0.10). We found insufficient intra- and interobserver consistency of breast radiologists in reporting BI-RADS assessment categories. Although training may improve these results, simpler alternative reporting methods (systems), focused on clinical decision-making, should be explored.

Citing Articles

Reliability of radiologists' first impression when interpreting a screening mammogram.

Gandomkar Z, Siviengphanom S, Suleiman M, Wong D, Reed W, Ekpo E PLoS One. 2023; 18(4):e0284605.

PMID: 37098013 PMC: 10128970. DOI: 10.1371/journal.pone.0284605.


Can Pre-biopsy Second-Look Breast Ultrasound Affect Clinical Management? Experience From a Single Tertiary Hospital.

Ma L, Qin J, Kong L, Zhao J, Xiao M, Wang H Front Oncol. 2022; 12:901757.

PMID: 35712464 PMC: 9192959. DOI: 10.3389/fonc.2022.901757.


Is biopsy necessary? Role of DCE-MRI in BIRADS-3 lesions.

Turk G, Ozdemir M, Coban M, Koc A Diagn Interv Radiol. 2020; 26(6):552-556.

PMID: 32990245 PMC: 7664750. DOI: 10.5152/dir.2020.19455.


Comparison of breast density assessments according to BI-RADS 4th and 5th editions and experience level.

Akdogan Gemici A, Bayram E, Hocaoglu E, Inci E Acta Radiol Open. 2020; 9(7):2058460120937381.

PMID: 32733694 PMC: 7372628. DOI: 10.1177/2058460120937381.


Measuring intrarater association between correlated ordinal ratings.

Nelson K, Zhou T, Edwards D Biom J. 2020; 62(7):1687-1701.

PMID: 32529683 PMC: 7649720. DOI: 10.1002/bimj.201900177.