Background: Because palpitations and light headedness often occur paroxysmally these complaints are difficult to diagnose. The hazards for a GP are too many diagnostic interventions for worried well and too few diagnostics for potentially life threatening complaints.

Objectives: Patient-activated memo event recorders have proved to be successful in diagnosing episodes of cardiac arrythmias in secondary care. We tested the diagnostic yield of these devices in general practice.

Methods: A randomized clinical trial in general practice. Consecutive patients with complaints of palpitations or light-headedness were randomized to either usual care or usual care plus event-recorder. The main outcome was the difference in explained episodes. Secondary outcomes were the differences in the number and character of cardiac diagnoses and the feasibility of the event-recorder.

Results: There were fewer patients without a diagnosis in the intervention group (17% vs 38%; RR = 0.5, 95% CI 0.3 to 0.7) and more patients with a cardiac diagnosis (67% vs. 27%: RR 2.5, CI 1.8 to 3,5). More relevant cardiac arrhythmias were detected (22% vs 7%) with event recording than with usual care (RR 3.2, 95% CI 1.5 to 6.8).

Conclusion: Patient-activated loop recorders are feasible and effective diagnostic tools in patients with palpitations or light-headedness in primary care. More research into patient characteristics and selection criteria is needed to fine-tune the use of these devices in primary care.

Citing Articles

Heart failure and central sleep apnea in the era of implantable recorders.

Cabac-Pogorevici I, Revenco V Anatol J Cardiol. 2021; 25(4):216-224.

PMID: 33830042 PMC: 8923486. DOI: 10.5152/AnatolJCardiol.2021.63668.


Diagnostic Accuracy of a Smartphone-Operated, Single-Lead Electrocardiography Device for Detection of Rhythm and Conduction Abnormalities in Primary Care.

Himmelreich J, Karregat E, Lucassen W, van Weert H, de Groot J, Handoko M Ann Fam Med. 2019; 17(5):403-411.

PMID: 31501201 PMC: 7032908. DOI: 10.1370/afm.2438.


Optimal duration and predictors of diagnostic utility of patient-activated ambulatory ECG monitoring.

Tan E, Seow S, Kojodjojo P, Singh D, Yeo W, Lim T Heart Asia. 2018; 10(2):e011061.

PMID: 30555536 PMC: 6267449. DOI: 10.1136/heartasia-2018-011061.


2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry.

Steinberg J, Varma N, Cygankiewicz I, Aziz P, Balsam P, Baranchuk A Ann Noninvasive Electrocardiol. 2017; 22(3).

PMID: 28480632 PMC: 6931745. DOI: 10.1111/anec.12447.


Systematic screening for the detection of atrial fibrillation.

Moran P, Teljeur C, Ryan M, Smith S Cochrane Database Syst Rev. 2016; (6):CD009586.

PMID: 27258214 PMC: 7105908. DOI: 10.1002/14651858.CD009586.pub3.