» Articles » PMID: 1593061

Lesion Morphology and Coronary Angioplasty: Current Experience and Analysis

Overview
Date 1992 Jun 1
PMID 1593061
Citations 34
Authors
Affiliations
Soon will be listed here.
Abstract

From July 1, 1990 to February 28, 1991, 533 consecutive patients with 764 target vessels and 1,000 lesions underwent coronary angioplasty. Procedural success was achieved in 92.3%, untoward (major cardiac) events occurred in 3% (0.8% myocardial infarction, 1.3% emergency coronary bypass grafting and 0.9% both; there were no deaths). An unsuccessful uncomplicated outcome occurred in 4.7%. Lesion analysis using a modified American College of Cardiology/American Heart Association classification system showed that 8% were type A, 47.5% were type B and 44.5% were type C (36% of type B and 11% of type C were occlusions). Angioplasty success was achieved in 99% of type A, 92% of type B and 90% of type C lesions (A vs. B, p less than 0.05; B vs. C, p = NS; A vs. C, p less than 0.01). Untoward events occurred in 1.2% of type A, 1.9% of type B and 2% of type C lesions (p = NS). An unsuccessful uncomplicated outcome occurred in 0% of type A, 6% of type B and 7% of type C lesions (A vs. B, p less than 0.05; B vs. C, p = NS; A vs. C, p less than 0.05). Among the unsuccessful uncomplicated outcome group, occlusion occurred in 49%: 38% of type B and 59% of type C lesions. With B1 and B2 subtypes, success was obtained in 95% and 89.5% and untoward events occurred in 1.5% and 2.3% and an unsuccessful uncomplicated outcome in 3.7% and 8%, respectively. C1 and C2 subtyping showed success in 91% and 86%, untoward events in 1.3% and 6% and an unsuccessful uncomplicated outcome in 7.5% and 8.5%, respectively. Among the 764 vessels, success was obtained in 89.5% and untoward events occurred in 2.5% and an unsuccessful uncomplicated outcome in 8%. Assessment of lesion-vessel combinations showed a less favorable outcome with type C lesions and combinations of A-B, B-C and multiple (more than three lesions) type B and C vessels. Statistical analysis of morphologic factors associated with angioplasty success included absence of (old) occlusion (p less than 0.0001) and unprotected bifurcation lesion (p less than 0.001), decreasing lesion length (p less than 0.003) and no thrombus (p less than 0.03). The only significant factor associated with untoward events was the presence of thrombus (p less than 0.003). Predictors of an unsuccessful uncomplicated outcome included old occlusion (p less than 0.0001) and increasing lesion length (greater than 20 mm) (p less than 0.001), unprotected bifurcation lesion (p less than 0.05) and thrombus (p less than 0.03).

Citing Articles

Endovascular Drug Delivery.

Lungu C, Creteanu A, Mehedinti M Life (Basel). 2024; 14(4).

PMID: 38672722 PMC: 11051410. DOI: 10.3390/life14040451.


STEMI patients receiving percutaneous coronary intervention for a culprit lesion with coronary artery bifurcation-efficacy and safety of the jailed semi-inflated balloon.

Lin T, Chen K, Hu Y, Chang K, Lai C, Liu T Front Cardiovasc Med. 2023; 10:1132062.

PMID: 37456820 PMC: 10349388. DOI: 10.3389/fcvm.2023.1132062.


Utility of the ACC/AHA Lesion Classification to Predict Outcomes After Contemporary DES Treatment: Individual Patient Data Pooled Analysis From 7 Randomized Trials.

Konigstein M, Redfors B, Zhang Z, Kotinkaduwa L, Mintz G, Smits P J Am Heart Assoc. 2022; 11(24):e025275.

PMID: 36515253 PMC: 9798816. DOI: 10.1161/JAHA.121.025275.


Elevated levels of sIL-2R, TNF-α and hs-CRP are independent risk factors for post percutaneous coronary intervention coronary slow flow in patients with non-ST segment elevation acute coronary syndrome.

Wang C, Wu Y, Su Y, Mao B, Luo Y, Yan Y Int J Cardiovasc Imaging. 2022; 38(6):1191-1202.

PMID: 35182256 PMC: 11143008. DOI: 10.1007/s10554-022-02529-8.


Rationale, Design, and Implications of Bifurcation Coronary Stenting: Insight from the Indian Bifurcation Stenting (IBIS) Registry.

A J, Malviya A, Thomas J, S V, Mandalay A, Joseph J Cureus. 2021; 13(9):e18027.

PMID: 34671518 PMC: 8520440. DOI: 10.7759/cureus.18027.