» Articles » PMID: 15895569

Effects of X-ray and CT Image Enhancements on the Robustness and Accuracy of a Rigid 3D/2D Image Registration

Overview
Journal Med Phys
Specialty Biophysics
Date 2005 May 18
PMID 15895569
Citations 6
Authors
Affiliations
Soon will be listed here.
Abstract

A rigid body three-dimensional/two-dimensional (3D/2D) registration method has been implemented using mutual information, gradient ascent, and 3D texturemap-based digitally reconstructed radiographs. Nine combinations of commonly used x-ray and computed tomography (CT) image enhancement methods, including window leveling, histogram equalization, and adaptive histogram equalization, were examined to assess their effects on accuracy and robustness of the registration method. From a set of experiments using an anthropomorphic chest phantom, we were able to draw several conclusions. First, the CT and x-ray preprocessing combination with the widest attraction range was the one that linearly stretched the histograms onto the entire display range on both CT and x-ray images. The average attraction ranges of this combination were 71.3 mm and 61.3 deg in the translation and rotation dimensions, respectively, and the average errors were 0.12 deg and 0.47 mm. Second, the combination of the CT image with tissue and bone information and the x-ray images with adaptive histogram equalization also showed subvoxel accuracy, especially the best in the translation dimensions. However, its attraction ranges were the smallest among the examined combinations (on average 36 mm and 19 deg). Last the bone-only information on the CT image did not show convergency property to the correct registration.

Citing Articles

3D-2D Deformable Image Registration Using Feature-Based Nonuniform Meshes.

Zhong Z, Guo X, Cai Y, Yang Y, Wang J, Jia X Biomed Res Int. 2016; 2016:4382854.

PMID: 27019849 PMC: 4785510. DOI: 10.1155/2016/4382854.


Evaluation of Image Enhancement Method on Target Registration Using Cone Beam CT in Radiation Therapy.

Yan H, Lei R, Wu J, Di F, Yin F Clin Med Oncol. 2011; 2:289-99.

PMID: 21892290 PMC: 3161701. DOI: 10.4137/cmo.s512.


Validation for 2D/3D registration. II: The comparison of intensity- and gradient-based merit functions using a new gold standard data set.

Gendrin C, Markelj P, Pawiro S, Spoerk J, Bloch C, Weber C Med Phys. 2011; 38(3):1491-502.

PMID: 21520861 PMC: 3089767. DOI: 10.1118/1.3553403.


Automatic registration of CT volumes and dual-energy digital radiography for detection of cardiac and lung diseases.

Fei B, Chen X, Wang H, Sabol J, DuPont E, Gilkeson R Conf Proc IEEE Eng Med Biol Soc. 2007; 2006:1976-9.

PMID: 17945687 PMC: 2743908. DOI: 10.1109/IEMBS.2006.259888.


A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Munbodh R, Chen Z, Jaffray D, Moseley D, Knisely J, Duncan J Med Phys. 2007; 34(7):3005-17.

PMID: 17822009 PMC: 2796184. DOI: 10.1118/1.2745235.