» Articles » PMID: 15844516

Comparison of Liquid Chromatography Using Triple Quadrupole and Quadrupole Ion Trap Mass Analyzers to Determine Pesticide Residues in Oranges

Overview
Journal J Chromatogr A
Publisher Elsevier
Specialty Chemistry
Date 2005 Apr 23
PMID 15844516
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Liquid chromatography-triple quadrupole/mass spectrometry (LC-TQ/MS) and liquid chromatography-quadrupole ion trap/mass spectrometry (LC-QIT/MS) for determining bupirimate, hexaflumuron, tebufenpyrad, buprofezin, pyriproxyfen, and fluvalinate in fruits have been compared. The differences in the mass spectra obtained by triple and ion trap quadrupoles are discussed, showing how both of them provide interesting features. The evaluation of the two instruments was carried out by ethyl acetate extraction of oranges spiked with the studied pesticides at LOQ and 10 times the LOQ. Results obtained by LC-TQ/MS correlated well with those obtained by LC-QIT/MS. Recoveries were 70-94% by LC-TQ/MS and 72-92% by LC-QIT/MS with the R.S.D. from five replicate analysis 4-14% and 8-18%, respectively. Matrix effects were tested for both techniques by standard addition to blank extracts. Although the matrix effects are not originated in mass analyzer but in the LC/MS interface, they were, generally, more marked by LC-QIT-MS than by LC-TQ/MS. The limits of quantification (LOQs) were 0.005-0.2 mg kg(-1) by both equipments--appropriate values for determining these pesticides in orange from the regulatory point of view. The results indicate that the TQ provides higher precision, better linearity, it is more robust, and when the purpose of the analysis is quantitative determination, preferable over the QIT. However, the application of both mass spectrometers to analyze orange samples conventionally treated showed that any can be used for qualitative and quantitative purposes.

Citing Articles

Consumer Safety and Pesticide Residues: Evaluating Mitigation Protocols for Greengrocery.

Popescu Stegarus D, Oprita Cioara C, Tamaian R, Niculescu V J Xenobiot. 2024; 14(4):1638-1669.

PMID: 39584953 PMC: 11587004. DOI: 10.3390/jox14040088.


Research Progress on Benzimidazole Fungicides: A Review.

Bai S, Zhang M, Tang S, Li M, Wu R, Wan S Molecules. 2024; 29(6).

PMID: 38542855 PMC: 10975326. DOI: 10.3390/molecules29061218.


Determination of the Dissipation Dynamics and Terminal Residue of Bupirimate and Its Metabolites in Cucumber by QuEChERS-Based UPLC-MS/MS.

Chen Y, Gao D, Wu Y, Wang L, Fan W, Gao Y ACS Omega. 2023; 8(26):23975-23981.

PMID: 37426269 PMC: 10323959. DOI: 10.1021/acsomega.3c02644.


Τemporal Variation in Pesticide Residues in Citrus Fruits from Chios, Greece, before and after the Development of an Integrated Pest Management Strategy (IPMS): A Five-Year Study (LIFE13 ENV GR/000414).

Bempelou E, Anagnostopoulos C, Kiousi M, Malatou P, Liapis K, Kouloussis N Toxics. 2021; 9(12).

PMID: 34941757 PMC: 8705237. DOI: 10.3390/toxics9120323.


Pulsed Nano-Electrospray Ionization: Characterization of Temporal Response and Implementation with a Flared Inlet Capillary.

Bushey J, Kaplan D, Danell R, Glish G Instrum Sci Technol. 2011; 37(3):257-273.

PMID: 21785563 PMC: 3141176. DOI: 10.1080/10739140902831313.